Re-adjustement of end limits
8.1- Re-adjustement of UP end limits:
1- Position the motor on the UP end limit previously set in
§4.3b with the UP key.
2- Press simultaneously for 5 seconds the UP and DOWN
keys, The motor will run for 0,5 second in one direction
and then in the other direction.
3- Adjust the new position with the UP and DOWN keys.
4- Validate the new position by pressing 2 seconds the Stop
key. The motor will run for 0,5 second in one direction and
then in the other direction. The new end limits setting is
memorized.
8.2- Re-adjustement of DOWN end limits:
1- Position the motor on the DOWN end limit previously set
in §4.3a with the DOWN key.
2- Press simultaneously for 5 secondes the UP and DOWN
keys, The motor will run for 0,5 second in one direction
and then in the other direction.
3- Adjust the new position with the UP and DOWN keys.
4- Validate the new position by pressing 2 seconds the
Stop key. The motor will run for 0,5 second in one direc-
tion and then in the other direction. The new end limits
setting is memorized.
9
Cancelling programming and settings
9.1- Switch off the power supply to the motor for 2 seconds.
9.2- Switch the power to the motor back on for 7 seconds.
9.3- Switch off the power supply to the motor for 2 seconds.
9.4- Switch the power to the motor back on.
- If the motor is on the end limit position (up or down), the
motor will run briefly on one direction and then in the
other, otherwise, the motor runs for 5 seconds in random
direction. The motor is now in the "cancelling" mode.
If you switch off the power to several motors, they will all be in cancelling mode. That is why, you must
"eject" out of this mode all the motors that are not to be deleted by sending a command from their indivi-
dual control transmitter (UP or Down).
9.5- Then, validate the cancelling of the affected motor from the individual control:
- Press the PROG key of the transmitter more than 7
seconds. Maintain the pressure until the motor will first
run for 0,5 second in one direction and then the other, and
a few second later, it will run again in both direction.
The Hz.02 motor is now as it was originally configured, and no transmitter and no settings is saved in its memory
and is ready for a new programming.
Hereby, SIMU, declares that this equipment "T3.5Hz.02 / T5Hz.02 / T6Hz.02" is in compliance with the essential require-
ments and other relevant provision of Directive 2006/42/EC. A declaration of Conformity is available at the web address:
www.simu.com. Usable in EU, CH