Télécharger Imprimer la page

Simu T5 Hz.02 Mode D'emploi page 6

Publicité

2
Wiring
You must have the possibility to switch off individually each motor.
3
Compatible transmitters
1 : COLOR+ Wall Hz transmitter
2 : COLOR+ 1/5 channels Hz transmitter
3 : Color Multi 16 / Timer Easy / Timer Multi transmitters
4 : Sun sensor Hz
Transmitters range:
1, 2 & 3: 20 m through 2 concrete walls.
4: 6 m through 2 concrete walls.
12 transmitters max. for one motor.
Location of the PROG key on Hz transmitters:
Do not position the transmitter near metal in order to avoid range losses.
4
End limit adjustment
If the installation includes several motors, only one motor is to be powered during this programming
procedure. It will eliminate interferences with the other motor during the procedure.
4.1- Learning mode:
- Switch the motor ON.
- Simultaneously press the UP and DOWN keys of a Hz transmitter. The
motor will run for 0,5 second in one direction, then in the other. The
transmitter now controls the motor in unstable mode, move to
stage 4.2.
4.2- Checking the rotation direction:
Press the UP key of the transmitter:
a- If the motorized tube runs in the UP direction, move to next stage (4.3).
b- If the motorized tube runs in the DOWN direction, reverse the rotation direction by pressing the Stop key for at least 3 seconds. The motor
will confirm the reversal of the rotation direction by running for 0,5 second in one direction, then in the other direction. Move to the stage 4.3.
4.3- Adjustement of the end-limits : memorizing the end points:
The end-limit adjustement can be done in two ways:
- First you can memorize the DOWN position (a) and then the UP position (b).
- First you can memorize the UP position (b) and then the DOWN position (a).
2/4