19. Technical characteristics
• Charging station
Environmental conditions
Usage temperature
Storage temperature
Relative humidity
Protection
Maximum altitude of operation
Degree of pollution
Use
Electrical characteristics
Voltage
Usage frequency
Nominal insulation voltage Ui
Charging station electrical protection
Electrical protection of the charging station if Charging mode 2
supplied
Maximum charging current/power Mode 3 T2/T2S socket (depending
on version)
Maximum charging current/power Mode 2 TE socket (depending on
version)
Electrical protection rating
Overvoltage category
Earth connection diagram
Minimum/possible wiring
Mechanical characteristics
Weight
Maximum weight supported by the cable support affixed to the
charging station
Height
Width
Depth
Classification
Power input
Power output
Environmental and usage conditions
Location of
Type of mounting
Category equipment
Charging mode
Adaptor
Cable extension
• Identification of vehicle compatibility
All manuals and user guides at all-guides.com
-25°C to +50°C
-35°C to +70°C
5% to 95%
IP 55 – IK 10
2000 m
3
intended for use by ordinary people
230 V~ / 400 V~ (three-phase version) -15% / +10%
50/60 Hz +/- 1%
250 V~ / 500 V~
40 A circuit breaker, C curve, energy limitation class I²t 3, on a circuit
that cannot supply more than 6 kA in short-circuit (or equivalent)
16 A circuit breaker, C curve, energy limitation class I²t 3, on a circuit
that cannot supply more than 6 kA in short-circuit (or equivalent).
32 A - 7 kW (single-phase version) / 32 A - 22 kW (three-phase version)
16 A - 4 kW (single-phase version) / 16 A - 11 kW (three-phase version)
16 A - 4 kW
Class 1 (earth connection)
3
TN-S, TN-C-S, TT
10 mm² in single or multi strand/16 mm² in multi strand.
Only the use of a copper conductor is authorised.
6.2 kg
7 kg
549 mm
250.5 mm
173 mm
Electric Vehicle (EV) power system connected to the AC power supply
network (permanently connected)
alternate current power system for EV
indoor and outdoor use
equipment for restricted access areas and unrestricted access areas
surface mounting on wall mounting, on stand, fixed post, column and pipe.
Installation in a horizontal position on the ceiling or on the floor is prohibited
1
mode 3 via T2/T2S socket and mode 2 via TE socket depending on
version
no plug adapter can be used between the charging station and the
charging cable or between the charging cable and the car
the charging cable cannot be extended. The charging cable must be
in one piece and a maximum length of 7 m
55