TROUBLESHOOTING
Problem
Tool will not start.
Motor overheating
LED work light flashes
rapidly.
LED work light flashes
slowly.
Cause
1. Battery pack charge is
depleted.
2. Battery pack is not installed
properly.
3. Burned out switch.
Ventilation slots are obstructed.
The tool has stopped working to
protect internal electronics.
The battery charge is very low.
Remedy
1. Charge the battery.
2. Confirm that the battery is
locked and secured to the
tool.
3. Have the switch replaced
by an Authorized SKIL
Service Center or Service
Station.
Clean and clear the
ventilation slots. Do not cover
the slots with hand during
operation.
Release the trigger switch,
wait for the tool to cool down,
then and start the tool again.
Charge the battery.