Télécharger Imprimer la page

Inventum IKG6024WGRVS Mode D'emploi page 25

Publicité

Checking the operation
Ignite the burners. Check whether the flame profile is uniform and stable for the complete flexibility range.
Important for this is that:
1.
the flame does not smother in the simmer setting
2.
the burner does not 'blow off' at the maximum burn setting (to be recognized to flames that are at a distance from the
burner in combination with a 'hissing' sound)
3.
there a no tall yellow flames
Gas table
G25.3/25 mbar*
1
0.78 mm
2
1.00 mm
3
1.36 mm
* On pages 24 and 25 you can find more information about adjusting the appliance for different types of gas.
The appliance was configured for the appliance category K (I2K) and is suitable for the use of G and G+ distribution gases
according to the specifications as included in the NTA 8837:2012 Annex D with a Wobbe index of 43.46 – 45.3 MJ/m3 (dry, 0
°C, upper value) or 41.23 – 42.98 (dry, 15 °C, upper value).
This appliance can moreover be converted and/or be calibrated for the appliance category E (I2E).
This therefore implies that the appliance: "is suitable for G+ gas and H gas or is demonstrably suitable for G+ gas and can
demonstrably be made suitable for H gas" within the meaning of the "Dutch Decree of 10 May 2016 regarding amendment of
the Dutch Gas Appliances Decree...."
Manufacturer
Model
Type of hob
Number of cooking zones
Heating technology-1
Format-1
Energy-efficiency-1
Heating technology-2
Format-2
Energy-efficiency-2
Heating technology-3
Format-3
Energy-efficiency-3
Heating technology-4
Format-4
Energy-efficiency-4
Heating technology-5
Format-5
Energy-efficiency-5
Energy-efficiency of the hob
This hob complies to EN 30-2-1
G20/20 mbar
G30/30 mbar
0.78 mm
0.50 mm
1.00 mm
0.66 mm
1.41 mm
0.97 mm
kW
1 Simmer burner 1.0 kW
2 Semi-rapid burner 1.75 kW
1 Wok burner
3.6 kW
INVENTUM
IKG6024WGRVS
Gas
4
Gas
Help
%
N.v.t.
Gas
Normal
%
62,3
Gas
Normal
%
61,3
Gas
Rapid
%
57,0
-
-
%
-
%
60,2
25
English

Publicité

loading