1. Flow direction marked in the
cell must be respected.
Recirculation system must
guarantee the minimum flow
stated in the Table of Technical
Specifications for each model
(see Section 8).
Other configurations would only be acceptable in the case that they allow for detection of gas
bubbles when water flow through the cell is too low.
RECOMMENDED Installation
2. The system flow detector
activates if there is not
recirculation (flow) of water
through the cell or if flow is very
low. If electrolysis gases are not
properly removed through the
electrolysis cell, the generated
gas bubble electrically isolates
the auxiliary electrode
(electronic detection).
Therefore, when locating the
electrodes in the cell, the level
sensor (auxiliary electrode) will
have to be located in the higher
area of the cell. The safest
orientation is shown in the
recommended installation
diagram.
Fig. 5
Fig. 7
NOT ALLOWED installations
ALLOWABLE installation
5
3. WARNING: if the in-out
valves of the electrolysis cell
are closed simultaneously, the
flow detector (gas detector) will
not work correctly, with the
consequent risk of cell
breakdown. Although this
situation is extremely unusual, it
can be easily avoided once the
equipment has been installed,
by locking at opened position
the return valve to the
swimming pool, so it cannot
accidentally be manipulated.
Fig. 6
Fig. 8