4.
INSTALLATION:_____________________________________________________________
4.1.
Installation of the power supply
Always install the POWER SUPPLY of the salt electrolysis system VERTICALLY on a solid and
rigid surface (wall) as shown in the recommended installation diagram (Fig. 1). In order to
guarantee a good state of conservation, the POWER SUPPLY should be installed in a well-
ventilated dry place. Due to IP degree of the POWER SUPPLY the salt electrolysis system should
not be installed outdoors. The POWER SUPPLY should be installed a bit distant from the
electrolysis cell so that it cannot accidentally suffer water splashes.
4.2.
Installation of the electrolysis cell
The electrolysis cell is made of a transparent polymer in whose interior the electrodes are placed.
The electrolysis cell must be always installed indoors and after the pool filter, and after any other
equipment that may be present (heat pumps, control systems, etc.).
The installation of the cell should allow easy access to the installed electrodes by the user. It is
highly recommended to install the electrolysis cell in a place of the pipe that can be easily isolated
from the rest of the installation by two valves, so that the tasks of maintenance can be carried out
with no need of partial or total draining of the swimming pool.
Where the cell is installed on a by-pass (recommended option), a valve to regulate the flow must
be introduced. Prior to installation, please consider the following commentaries:
Fig. 2
Warning
Beware of corrosive atmosphere formation due to pH decreasing solutions
(specially, those ones based on hydrochloric acid "HCl"). Do not install the
salt electrolysis system near to any stores of these chemicals. We strongly
recommend the use of chemicals based on sodium bisulphate or diluted
sulphuric acid. Power supply must be connected to the electrical control box
of the pool, so that the pump and the salt electrolysis system are turned on
(and off) simultaneously.