en-us Checking the installation
junction box
Power supply
All models must be connected with the included 39" (1 m) flexible conduit.
Models
CI 482 602
CI 492 602
5.2 Connecting electrical supply
WARNING
Before installing, turn power OFF at the service panel.
Lock service panel to prevent power from being turned
ON accidentally.
Note: If the cooktop is installed and connected as speci-
fied here, it will be grounded in compliance with the Na-
tional Electrical Code.
Install a suitable junction box (not furnished).
1.
The branch-circuit breakers ampacity, the wire sizes
and the connections must conform to the requirements
of the National Electrical Code or Canadian Electrical
Code and all local codes and ordinances.
Attach the flexible conduit to the junction box.
2.
10
240 V AC, 3-wire, 60 Hz system: cir-
cuit breaker
30 A
50 A
Connect the lead wires to the junction box supply wires
3.
in proper phase.
– Black (L1) to black
– Red (L2) to red
– Green or bare to ground
6 Checking the installation
Checking the installation
Check if your unit is working properly after you have com-
Checking the installation
pleted the installation steps.
Before you turn on power supply, make sure all controls
are in the OFF position.
Remove everything from the cooktop surface including
1.
stickers.
flexible conduit approx. 3 ft. (900 mm)
208 V AC, 3-wire, 60 Hz system: cir-
cuit breaker
30 A
50 A
1
2
3
Red wires
1
UL listed wire connectors
2
Green (or bare) ground wire (from appliance)
3
Cable from home power supply
4
Black wires
5
Junction box
6
Flexible conduit from appliance
7
WARNING
4
5
6
7

Publicité