CONTROL PANEL NE266
GB
CONTROLS:
Push button with warning light for turning
INTERNAL LIGHTS on or off (*)
Push button with warning light for turning
INTERNAL LIGHTS on or off (*)
(*) Yellow light colour active load, green light colour deactive load
SCREENS:
The warning light goes on when the 230V mains is connected
The warning light goes on when
the 230V mains when the two batteries are in parallel verifing before the battery service voltage
Press the push button to see internal temperature on the display (
temperature (
If the temperature probe is faulty the wording "
The screen remains active for approx. 30 seconds.
Pressing this Key for viewing the level percentage % (0,25,50,75,100) of the its reservoir identified with the symbols S1.
If S1 is empty, the display flashes.
If the tank is wrongly connected, the display will show "
The screen remains active for approx. 30 seconds.
Repeatedly pressing this Key for viewing the level percentage % (0,100) of the its reservoir identified with the symbols
R1, R2.
If R1 or R2 are full, the display flashes.
If the tank is wrongly connected, the display will show "
The screen remains active for approx. 30 seconds.
Press the push button once to see the voltage on the service battery (B2), Press the push button
B2
again to see displays the % the remaining battery
The screen remains active for approx. 30 seconds.
Press the push button once to see the voltage on the
B1
again to see displays the % the remaining battery
The screen remains active for approx. 30 seconds.
ALARMS:
Batteries: Car battery (B1) less than 11,8V or Service battery (B2) less than 10V.
In this case there is a bleep (if enabled) and the flashing battery button that have generated the alarm
(for the first 30 seconds you see the value)
Hold for more than 3 seconds (
battery alarm
Hold for more than 3 seconds (
battery alarm
Tanks:
Tank S1 empty or Recovery tanks R1, R2 full.
In this case there is a bleep (if enabled) and the flashing symbol the corresponding tank that raised the alarm
(for the first 30 seconds you see the value)
Hold for more than 3 seconds (
drinking water tank.
Hold for more than 3 seconds (
recovery tank.
Beep:
Hold for more than 3 seconds (
confirmation beep button pressed, and alarm buzzers
This symbol appears when there is an error:
.
Serial cable connection is wrong
CONSUMPTION:
To turn on the control panel you must touch for 1 sec. the right or left side panel where there are the keys. The display will
show the panel firmware version for one second and then the firmware version for the shunt in use for a further second.
The panel after 30 sec. switches to standby mode by turning off all symbols except the keys
keys light up when you touch for 1sec. the right or left side panel.
On stand by (no active controls) the control panel with shunt NE185 consumes a total of approx 40mA. When the key
pressed the control panel turns itself off and total consumption is reduced to just 4mA.
If the service battery voltage drops below 10V, after 1 minute the control panel turns itself off, together with all live parts.
CONNECTIONS:
The back of the panel has a connector for serial connection (JP6), a connector for the optional external temperature probe
(JP10) and a connector for the optional remote internal temperature probe (JP8).
ENABLE CLEANING GLASS:
Hold on the button (
) more than 3 sec will lock all the push button for 1 minute.
the vehicle engine is running and the parallel batteries is active or in the presence of
). If you get the message "
) button can be disabled (show "
B1
) button can be disabled (show "
B2
) button can be disabled (show "
) button can be disabled (show "
) button can be disabled (show "
Push button with warning light for turning
PUMP on or off(*)
Push button with warning light for turning
AUX on or off (*)
), press the push button twice to view external
", the temperature sensor is not present.
" will appear
".
".
starter battery (B1)
, Press the push button
") or enabled (show "
") or enabled (show "
") or enabled (show "
") or enabled (show "
") or enabled (show "
4
") the low car
") the low service
") the alarm of the
") the alarm of the
") the the
and those of active loads.
is
GB