Télécharger Imprimer la page

Ingersoll Rand W7.5-D-A116 Manuel D'instructions page 9

Publicité

Screens for Resetting Maintenance Indicator
Other Information Displays
Alarm Log
A record of all alarm or warning events is kept in the alarm log.
Reset status is tracked as well. The alarm log is maintained as long as
the unit is powered and for up to three days after power is removed
from the control.
System Trends
The following additional information is available by selecting the
SYSTEM TRENDS from the MAIN screen: The control tracks the amount
of time the pumps are in use and compares that to the available time.
The ratio is displayed. The LOAD FACTOR is displayed for the most
recent 24 hour period.
Automatic Restart
When power is applied to the scroll enclosure com pressor control, the
display will illuminate and go to the MAIN screen. Settings will be retained
from the last time the system had power. The motors will not energize
until the ON button is pushed on the control switch beside the display.
(Only the JOG function will override the ON button). In the event of
a loss of power, the user must push the ON button to restore the
compressors to operation. If automatic restart is desired, go to the
SYSTEM SETUP screen PG2 and press the > arrow on the left selector
switch. To disable, press the < arrow.
RELEASED 01/Jul/2024 12:28:06 GMT
7.5-15 kW (10-20 HP) Scroll Enclosed Air Compressors
BACnet Setup
Opera on
Enclosed Mul plex Scroll 20 – 40HP
This Code
meaning
Is here
47672197001 • 04/17/24 • Rev. F
Page 9 of 19

Publicité

loading

Ce manuel est également adapté pour:

W7.5-d-a145W11-t-a116W11-t-a145W15-q-a116W15-q-a145