Transport by Crane
Place lift straps through fork holes at bottom of unit, creating a lift
point above the unit. Make sure all lifting devices are rated for the
maximum load.
Be sure to use pads in order to protect the panels.
NOTICE
Installation Site
1. The scroll compressor must be located in a clean, well lit and
well ventilated area. A contaminated area can clog the intake
filter and/or intake metal mesh.
2. The area should be free of excessive dust, toxic or flammable
gases, moisture, water and direct sunlight.
3. Never install the compressor where the ambient temperature
is higher than 104° F or where there is risk of condensation due
to hummidity. Condensation will cause electrical short circuit
and rusting of components.
4. Clearance must allow for safe, effective inspection and
maintenance.
5. If necessary, use metal shims or leveling pads to level the
compressor tank or basemount unit. Never use wood to shim
the unit.
Ventilation
1. If the scroll compressor is located in a totally enclosed room,
an exhaust fan with access to outside air must be installed.
2. Never restrict the cooling fan exhaust air or the intake cooling
air.
3. Vent the exhaust air outside to prevent the compressor from
operating at high temperatures and shutting down.
4. Never locate the compressor where hot exhaust air from other
heat generating units may be pulled into the unit.
RELEASED 01/Jul/2024 12:28:06 GMT
7.5-15 kW (10-20 HP) Scroll Enclosed Air Compressors
Suggested Ventilation System
10 F. The BTU capacity of the vent system should be sized for the full
operating HP rating of the compressor. Suggested fan capacity at 0
static pressure is shown below. If static pressure is higher, the fan
capacity should be increased.
Ventilation Capacity (CFM)
the compressor enclosure. The opening of the exhaust duct should
be about 6 inches or larger on each side than the vent openings on
the compressor top panel. The duct should not obstruct removal of
the top panel for service, leave at least 12 inches clearance. The cfm
capacity of the cooling fan should be increased to compensate for the
duct flow losses.
The temperature rise in the room must be kept to a maximum of
Model
An exhaust duct may be installed to capture the warm air exiting
W7.5-D W11-T W15-Q
2650
3885
5300
47672197001 • 04/17/24 • Rev. F