6.9 Connecting the pneumatic system
A compressed air hose with a minimum inner width of 6 mm is required for air supply. A shut-off valve in the
supply line is recommended. This allows the BRS-LCi to be quickly and simply depressurized in order to carry
out any installation and maintenance work.
Fig. 11
7 Operation
NOTE
• As the cleaning station BRS-LCi is integrated into a welding system, the operating instructions of the
• Make sure that the BRS-LCi cleaning station is operated with a front sheet only.
1 Switch on the robot control.
2 Start the welding process.
3 Stop the welding process.

8 Putting out of operation

NOTE
• As the cleaning station BRS-LCi is integrated into a welding system, putting out of operation depends
1 Switch off the robot control.
Compressed-air motor
Clamping cylinder Stroke cylinder
clamp
loosen
M
Z2
Y2
2
14
12
14
12
1
3
5
Connecting the pneumatic system
welding components, such as welding torch and robot control, must be observed during operation.
on the robot control. Please make sure that the shutdown procedures for all components integrated in
the welding system are strictly observed.
Compressed-air motor
back forward
Z1
S1
S2
2
14
12
Y1
4
2
14
12
14
14
12
14
5
1
3
Y3
4 2
14
12
14
12
5 1 3
7 Operation
M
E
V
P
Y4
4 2
12
12
5 1 3
Draw in from
bottle
6 bar
EN - 13