b)
Press the steam iron button or foot pedal to ensure there is no more steam
in the boiler. Loosen the safety filler cap slowly to release all the pressure.
c)
Slowly open the pressure cap (1) and refill to the required level with warm
water.
d)
Replace the cap, tighten and wait for it to build up pressure again.
Note: Failure to shut off the boiler when the warning light is on may result in damaging
the heating element, which will void the warranty.
run out of water and the low water light to go on. The low water warning light is a
safety feature.
Important
When you are finished using the boiler for the day, unscrew the fill cap slowly until you
hear a hiss to release the steam from the tank. This will eliminate the vacuum that may
cause damage to the pressure gauge.
For a longer life and better machine performance we suggest that you flush out the
boiler tank once a week. Flushing the tank will help slow the sediment/mineral buildup
that may occur.
To flush the boiler tank
(Be careful as the water will be very hot as it comes out of the tank):
1.
Release the excess steam still inside the boiler at the end of use
(see item #13 above).
2.
Turn off the steam switch power switch and unplug the boiler unit.
3.
Carefully open the filler plug cap.
4.
Make sure the clear drain tubing has been installed on to the blow-down
valve (drawing reference #10) situated on the lower right side of the
tank, and the tubing is draining into something that can hold hot water.
5.
Open the blow down valve. Drain the remaining water from the boiler tank.
6.
Close the valve.
Water Instructions
Use tap water or distilled water or 50/50 tap/distilled water in the appliance. Do not
use perfume or products containing alcohol in the appliance.
8
Please do not wait for the unit to