How to Assemble and Use
1.
Take the steam station from its packing and make sure all packing has been
removed (including the protective bags). Put the station on a flat and solid
surface.
2.
Your boiler is supplied with a plug on the drain valve (right side of tank), as well as
a plastic hose and fitting to secure the hose. Please remove the plug and install
the hose and fitting. This will allow you to follow the proper cleaning procedure
(ref. step #14). When finished draining the boiler, turn the drain valve off, remove
the hose and reinstall the plug.
3.
A) 7000IS – 7500IS: It is recommended to put the iron on the iron pad, (supplied)
as the pad will withstand the temperature of the iron.
B) 7000CJ – 7500CD: Screw the nozzle into the steam fitting and plug in the
4-pin receptacle for the electronic foot pedal.
C) 7000CD – 7500CD – 7500IS: Connect the steam gun or steam brush the
same way using the quick-connect for the steam hose.
4.
Insert the two-piece wand (2) into the flange on top of the boiler, tighten with
the side screw and attach the spring on the iron hose to the coil end of the wand
(7000IS, 7500IS, 7000CD, 7500CD models only).
5.
Before beginning any operation, make sure that the exhaust valve (10) is closed
and the drain hose is installed (ref. step #2).
6.
Unscrew the safety cap (1). Fill the boiler with a maximum of 1.85 gallons (7 litres)
of water for the 7000-series. Use the funnel supplied, making sure you do not
overfill the tank.
7.
Insert the plug into the electrical outlet; switch on the boiler (3) and steam
button (2). When the two button lights come on, the steam device and boiler are
working.
8.
For the 7000IS iron system, turn the iron plate's temperature regulating knob (6)
to the desired temperature.
9.
Wait approximately 30 minutes for the boiler to reach maximum pressure. Once
it reaches 60 PSI, the unit is now ready to operate.
10. Note: When you call for steam for the first time (after reaching full pressure) you
might notice a fast decrease in pressure. This is normal for the first time.
11. The steam station is ready for use.
12. Push the steam button or the foot pedal for steam.
Important: This steam product is equipped with a low water warning light (4). During
operation, if the light comes on, it indicates that the unit requires more water to
operate. If this occurs, please follow these steps.
a)
Turn off the boiler switch (3).