Using Control Panel 1
4. Constant Temperature Function
The constant temperature function automatically activates in standard mode. In economic mode, it
starts within the designated time frame. In sleep mode, the anti-freeze function runs automatically.
Once the constant temperature function is initiated, the circulation pump starts first, and the heat
pump activates shortly after. If the constant temperature function is turned off, the heat pump shuts
down first, followed by the circulation pump.
When the constant temperature function is enabled, the system regulates the heat pump's operation
based on water temperature and the set temperature, ensuring automatic temperature control.
The temperature control setting (standard model and economy mode) are as follows:
·
If the water temperature is ≥ the set temperature + 34°F (1°C), the cooling function of the heat
pump is activated;
·
If the water temperature is ≤ the set temperature - 34°F (1°C), the heating function of the heat
pump is activated;
·
If water temperature = set temperature, the heat pump stops.
To set the heat & cool time period (Economy mode and sleeping mode only):
·
When system is powered on, press " " till entering timing heating time period setting interface.
The correspondent time value will flash. Press " " and "
·
"1" and "2" in LCD stand for time period 1 and time period 2. " " and " " in LCD stand for starting
and ending time of time period.
·
The system will automatically store the value after timing heating setting.
7
" to adjust the time.
Using Control Panel 1
5. Timing water cycle
The control system offers two time periods for setting water circulation. Before using the Chill Therapy unit,
please configure these two time periods.
When the system operates in standard and economy mode, you can set the water cycle time periods.
In sleeping mode, the timing of the water cycle is not applicable.
In any time periods, the water cycle will be started, otherwise, it will turn off.
To set the water cycle time period:
·
When system is powered on, press " " to set the timer for water circulation. The correspondent
time value will flash. Press "
" and "
" to adjust the time.
·
"1" and "2" in LCD stand for time period 1 and time period 2. " " and "
for the starting and ending time.
·
The system will automatically store the value after setting the time of water circulation.
6. Freezing Proof
The freezing proof function will automatically work. When water temperture is lower than 37 °F
(4 °C), heating will be started. When the temperature reaches 48 °F (9 °C), heating will be turned off.
7. Circulation Pump
When the control system is powered on and operates neither in sleeping mode nor setting mode,
press the key " " to control the circulation pump.
Circulation pump will turn off automatically after running for 30 minutes.
" in LCD stand
8