3.12 Dehumidification capacity
The image shows the daily dehumidification capacity of the product. This capacity is based
on a room temperature of 30°C measured by the product, 80% relative humidity and when
the air outlet is fully open. At different temperatures and relative humidity, the product may
have a different capacity.
At the same room temperature, the dehumidification capacity is higher at higher
relative humidity and lower at lower relative humidity. At the same relative humidity, the
dehumidification capacity is higher at higher temperatures and lower at lower temperatures.
If the product is placed in a cabinet, the dehumidification capacity may decrease
significantly shortly after use, that is, the humidity in the cabinet has decreased significantly.
NOTE
◊
Please note that it may take ±3 minutes before the dehumidification program will start.
◊
The efficiency of the product is affected by the air. Preferably keep windows and doors
closed in the room where the product is placed.
◊
For safety reasons, the product will automatically shut down when the temperature
reaches ±36°C in the room where the product is placed.
◊
Due to circulation of the coolant, the product may make noise when starting up. When
the circulation is stable, the noise will decrease.
4. Troubleshooting
If the following problems occur while using the product, refer to the table below to find a
solution. If the problems cannot be solved using these options, please contact our customer
service.
Humidity 80%
Room temperature
English