- check main burner ignition and flame for minimum performance
- check if the burner flame is licking the thermoelement and if it is blue
- we recommend that the user comply with the instructions when using the device
Flame regulation by lower efficiency:
Set the low output then adjust the flame using the screw located in the faucet body next to the faucet shaft.
Setting process:
- remove the adjustment tap button (pull towards you)
- There is a slot for adjustment next to the faucet shaft.
- Adjust the flame using the small flat screw.
Ignition of the burner and adjustment of the power
Turn the relevant burner adjustment knob (A) to the "main burner ignition" position, then press and hold it. Light
the burner with a lighter or matches. After lighting the burner, hold button (A) pressed for several seconds until
the hot melt becomes hot. Then release the button. If the flame goes out, repeat the entire process.
Power reduction performance:
By turning the knob (A) to the "reduced power" position, you regulate the combustion of the burner at reduced
power (lower performance).
How to turn off the burner:Turn the knob (A) to position "0"
Turn the main burner adjustment knob (1) to the "main burner ignition" position, then push it in and hold it
down. Light the auxiliary burner using a lighter or matches. The auxiliary burner is located in the burner cover
opening. After lighting the auxiliary burner, keep button (1) pressed for several seconds until the hot melt
becomes hot. Then release the button. If the flame goes out, repeat the operation until the main burner
ignites by turning the knob (1) to the full power position.
Ignition of the main perpetual flame burner in waiting position (images A,B) (*)
Turn the burner adjustment knob (1) to the "additional burner ignition" position. The main burner flame goes
out and only burns the auxiliary burner flame, which is ready for the burner to ignite main.In case you do not
use the burner for a long time, also turn off the combustion of the auxiliary burner by placing it in the "0"
position.
Switch Off
Light the additional burner
Full power
Low power
EN