GB
installation
PRECAUTIONS
PRIOR TO INSTALLATION
To avoid hampering the module's effi cient
operation, the installation site must be pro-
tected against atmospheric agents.
The module is designed for being installed
on the wall or directly on the storage tank
(if appropriately confi gured). It therefore
cannot be installed on a fl oor-standing
base or on the fl oor. When creating a tech-
nical compartment for housing the module,
leave suffi cient space around the module to
ensure easy accessibility.
Verify that all the module's components
have remained intact following transport
and handling, and have not been damaged
by knocks.
In case of evident damages to the product,
do not proceed with installation.
CAUTION
When drilling the wall, take care not to
damage any electrical wiring or existing
piping.
MOUNTING BRACKET
28
80
80
WALL INSTALLATION
After identifying a suitable wall, position
the mounting bracket using a spirit level.
Fix the module's mounting bracket to the
wall using the wall plugs provided. Insert
the screws and tighten carefully, while
making sure that the bracket lies level.
If the wall plugs provided are not suitable
for the type of chosen wall, replace them
using expansion plugs suitable for the type
of wall and weight of the module.
Insert the rear heat-insulating casing onto
the previously installed mounting bracket
and push it fully against the wall; place
the entire hydraulics unit inside the latter
by hooking it onto the mounting bracket;
make sure that it adheres properly to the
heat-insulating casing.
Verify that the entire module rests fully
against the wall and lies level, both hori-
zontally and vertically.
If not, perform the necessary adjustments
by intervening on the bracket's fi xing
screws.
200
80
400
80