Installation Instructions:

The appliance must be installed and commissioned by a qualified technician in accordance with established
regulations and local health and safety regulations..
1.
Before performing any operations, disconnect the appliance from the electricity mains using the external
switch.
2.
Open the two screws located at the bottom of the device and remove the cover from base.
3.
Fix the base horizontally against a wall or side of cabinet, the inlet and outlet water pipes are on the
down/bottom side of the unit. Use the three mounting screws provided.
108 mm
1.
2.
3.
.
Use the supplied water filter on the inlet water pipe line (see diagram)
4.
5.
Connect the incoming water line (cold only) to the inlet water pipe on the bottom right side and the
outgoing water line to the outlet water pipe on the bottom left side. Open the mains cock of water
supply and check there is no water leakage from the unit.
6.
Use a two-pole switch conforming with national laws in force (contact gap of at least 3 mm, preferably
equipped with fuses) to disconnect the appliance's power supply.
7.
Connect the power cable to the terminal block inside the unit. The appliance must be earthed and the
earth cable must be fixed to the terminal marked by the symbol
8.
Turn on the unit and check that it is operating as required.
9.
Reconnect the cover to the base with 2 screws.
10. It is required that a Ground Fault Circuit Interrupter/Earth Leakage Circuit Breaker be incorporated in the
circuit.
11. Make sure to install in the right way the pressure relief valve (supplied with the product)
before Inlet pipe.
12. It is required to install a flow control restrictor (AERATOR) at the sink or shower.
13. WARNING: UNIT MUST BE PROPERLY GROUNDED
14. THIS HEATER MUST HAVE ITS OWN INDEPENDENT CIRCUIT USING A CORRECTLY RATED CIRCUIT
BREAKER AND SUITABLE WIRE, SEE TABLE RECOMMENDED CABLE.
WARNING: If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or
similarly qualified persons in order to avoid a hazard.
248 mm
140 mm
5
Flow restrictor
cable
Hot
Cold
water
water in
out
only
.
EN
AERATOR