Electrical Connection
AMP JPT Connector
Deutsch Connector
PVE LED farver
PVE LED Colors
PVE LED Farben
PVE LED couleurs
The colour of on board LED re ects status of S5 valve.
LED Color
Flashing between orange and green
Orange
Green
Flashing green
Flashing orange
Red
© Danfoss, 2014-03
Pin.no.
Connection / signal
1
Can_L
2
VBAT / U_DC
3
GND
4
Can_H
Pin.no.
Connection / signal
1
Can_H
2
Can_L
3
VBAT / U_DC
4
GND
PVE software status
PVE is in bootloader / service mode
PVE is in disabled state and there are no (non-info type of) errors present
PVE is enabled and spool is at neutral position
Spool is steered outside of the dead band as a result of receiving a
non-zero setpoint through the CAN-BUS
A Warning, Critical or Severe error of is present in the system or the PVE is
in power save mode
Internal handshake aliveness communication fault or CAN controller
initializing failure or inability to recover from BUS-o