Functional description
The pump is fitted with a float switch,
which automatically switches the equip-
ment on or off.
The motor is protected from overload by a
thermal safety switch.
Please refer to the following descriptions
for the function of the operating parts.
Overview
1 Round handle
2 Pump housing
3 Pump outlet
4 Floor plate
5 Foot part
6 Mains connection cable
7 Float switch
8 Float switch grating
9 Reducer
10 Angle adapter
11 8 m nylon cord
Technical Data
Rated voltage ...................... 230 V~50 Hz
Rated power input/
Power consumption ........................ 400 W
Max. discharge rate (Q max) ........8000 l/h
Max. discharge head (H max) ............ 5 m
Max. depth of immersion .................... 5 m
Max. water temperature (T max) ..... 35 °C
Hose connection ..................1", 1¼ ", 1½ "
Max. foreign body size................... 25 mm
Mains cable ...................................... 10 m
Weight (incl. accessories) ...approx. 3,5 kg
Safety class ............................................. I
Degree of protection ..........................IPX8
Technical and optical changes can be
carried out in the course of further devel-
opment without notice. All dimensions,
references and information of this instruc-
tion manual are without guarantee. Legal
claims, which are made on the basis of
the instruction manual, cannot thus be
considered as valid.
Performance data
The maximum performance data are
measured with a straight, direct outlet
flow. The angle piece and backflow valve
may reduce performance.
6
5
4
3
2
1
0
2.500
Notes on Safety
This section deals with the general safety
regulations for working with the equip-
ment.
Symbols in the manual
Warning symbols with informa-
tion on damage and injury pre-
vention.
GB
10.000
5.000
7.500
Q[l/h]