EKKO ART
CONTROL
ACCESSORIES OPERATION
STEP-BY-STEP BUTTON (COM-K BUTTON)
If DIP6 ON => It cyclically performs the commands open-stop-close-stop-open etc.
If DIP6 OFF => Opens the gate when closed. There is no effect if activated while opening. If activated when gate
is open, the gate closes. If activated while closing, the gate reopens.
OPEN BUTTON (COM-OPEN)
The button controls the opening movement when the gate is stationary. If activated while closing, it reopens
the gate.
CLOCK FUNCTION OF OPEN BUTTON
ATTENTION: A CLOCK CONNECTED TO RS12 ACTIVATES THE OPENING MOVEMENT OF THE GATE
WITHOUT HAVING THE PROTECTION OF THE SAFETY DEVICES!
CLOSE BUTTON (COM-CLOSE)
Controls the closing movement when the gate is stationary.
REMOTE CONTROL
If DIP6 ON => It cyclically performs the commands open-stop-close-stop-open etc.
If DIP6 OFF => Opens the gate when closed. There is no effect if activated while opening. If activated when gate
is open, the gate closes. If activated while closing, the gate reopens.
PEDESTRIAN OPEN BUTTON (COM-PED.BUTT.)
Partial opening and closing control. During pedestrian opening, pausing or closing, you can control the opening
of any command linked to the RS12 board. With DIP 6 you can choose the operation mode of the pedestrian
push button.
If DIP6 ON => It cyclically performs the commands open-stop-close-stop-open etc.
If DIP6 OFF => Opens the gate when closed. There is no effect if activated while opening. If activated when gate
is open, the gate closes. If activated while closing, the gate reopens.
ELECTRIC LOCK (LOCK)
Set DIP 8 to ON to enable control of the electric lock when opening.
ELECTRIC LOCK PULSE RELEASE IN OPENING
Set DIP 9 to ON to enable the electric lock pulse release when opening (provided DIP 8 is ON).
If a command to open the gate is given when the gate is closed, the closing movement is performed for 0.5
seconds and the electric lock is simultaneously activated (followed by a 0.5 second pause and then the opening
of the gate).
ELECTRIC LOCK PULSE ENGAGEMENT
Set DIP 10 to ON to enable the pulse engagement of the electric lock when closing. Upon closing, motors are
activated for 0.5 seconds at full voltage to ensure lock engagement.
EASY MOTOR RELEASE
Set DIP 11 to ON to enable easy manual release (provided that DIP 10 is ON), upon closing a reverse motion
with a fixed time of 0.2 seconds occurs to facilitate manual release.
OPERATION OF SAFETY ACCESSORIES
PHOTOCELL (COM-PHOT)
DIP 4 OFF => if an obstacle is placed in range of the photocells when the gate is closed, the gate does not
open. During operation, photocells work when opening (by starting the opening movement only
after the obstacle is removed) and closing (by starting the reverse movement only after the
obstacle is removed).
DIP 4 ON => if an obstacle is placed in range of the photocells when the gate is closed and the command to
open is given, the gate opens (the photocells do not work while opening). Photocells work only
during closing (with reverse motion restored after a second, even if they are still engaged).
CONTROL OF IMMEDIATE CLOSING AFTER MOVEMENT IN FRONT OF PHOTOCELLS
DIP 16 ON and DIP 4 OFF =>
one second after the photocells are disengaged.
DIP 16 ON and DIP 4 ON => if photocells are engaged during opening, the gate continues to open. Upon
disengagement of the photocells, the gate stops and reverses closing motion after
a one second pause.
If total opening is reached (end of opening time), immediate closing is
deactivated and automatic time closing is activated (if TCA trimmer is
activated and LED DL6 is on). If during closing there is a rapid movement
(e.g. pedestrian) the gate will open again for two seconds and then close
once again.
DIP 12 OFF =>
immediate closing after movement in front of the photocells is deactivated.
N.B.: Please check photocell operation at least every six months.
EDGE (SAFETY STRIP) (COM-EDGE)
If engaged during opening, reverses the motion when closing.
If engaged when closing, reverses the motion when opening.
If it remains engaged again, it performs a further reversal after 2 seconds, then performs an additional short
reversal and then gives the sensor failure or engaged alarm (N.O. contact).
If the sensor remains engaged (N.O. contact) no movement is allowed.
If not used, jump the terminals COM-EDGE.
MONITORING OF SAFETY SENSORS (A+ TEST A-)
Sensors can be monitored through the A+ TEST input and DIP 12 ON.
The monitoring consists of a functional test of the sensor run after every full gate opening.
Closing the gate is therefore permitted only if the sensors have passed the functional test after each opening.
20
if photocells are engaged during opening, the gate stops and the gate only closes
CAUTION: MONITORING OF THE SENSOR INPUT CAN BE ACTIVATED WITH DIP 12 ON OR
DEACTIVATED WITH DIP 12 OFF. IN FACT, THE FUNCTIONAL TESTING OF SENSORS IS 'POSSIBLE
ONLY IF THESE DEVICES HAVE THEIR OWN POWER SUPPLY.
A MECHANICAL SENSOR CAN NOT BE MONITORED, SO DIP 12 SHOULD BE SET TO OFF.
SENSOR AUTOTEST ALARM (DIP 12 ON)
If the sensor fails the monitoring test after opening, an alarm is displayed by the blinker lighting up. Gate closure
is not allowed in this condition. Normal operation can be restored only by repairing the sensor and pressing one
of the activated controls.
STOP BUTTON (COM-STOP)
The STOP button stops the gate during any operation.
If held when the gate is fully open (or partially when using the pedestrian control) automatic closing is temporarily
deactivated (if activated by the TCA trimmer and LED DL6 on). It is therefore necessary to use a new command
to make it close.
The automatic closing function is reactivated on the next cycle (if activated by the TCA trimmer and LED DL6 on).
POWER SENSOR ALARM
The RS12 control panel has automatic sensors that make the movement of the gate reverse in case of impact
against objects or persons in accordance with the current EN standards (always use the right tool to ensure
compliance with the values imposed by the standard), without special adjustments on the control panel, as it
operates using special internal software. If the power sensor is used in opening or closing (only in high-speed)
and then again, in the opposite direction, the gate stops and then reverses for 1 second.
The alarm status will be displayed by the blinker which will remain active for one minute, during which time you
can restore gate operation by pressing any command button.
FUNCTIONING IN DEAD MAN MODE WHEN THE SAFETY DEVICES ARE FAILING
If the safety edge fails or remains engaged for more than 5 seconds, or if photocell fails or remain engaded for
more than 60 seconds, the open, close, k button and pedestrian commands will work only in dead man mode.
The signal that this mode has been activated is given by the blinking of the programming led.
With the blinking of the programming led, the opening and closing operation are allowed only with the command
button pressed and held. The radio commands and that of automatic closing, will be excluded, since their use
in this mode, is not allowed by the norms.
Once the failing safety device is repaired, in automatic after 1 second, all standard commands that were
selected, such as step by step, automatic mode, radio commands and automatic closing start functioning again.
Note 1: during this functioning in dead man mode, in case of damage to the safety strips (or photocells) the
photocells (or safety strips) still work by interrupting the operation in progress.
Note 2: the stop command is not to be considered a safety command that can be bypassed in this mode.
Therefore, when pressed or damaged, it will not allow any movement of the gate.
The dead-man operation is only an emergency operation which must be activated for a very short period
and with the complete installation at sight so to have a secure and safe control of the system. As soon
as possible however, the failing safety devices must be repaired and activated.
BLINKER
N.B.: This control panel can power blinkers (ELA1) with lamps up to 24 V and 20 W.
PRE-BLINKING
DIP 5 - OFF => the motor and blinker begin simultaneously.
DIP 5 - ON => the blinker begins 3 seconds before the motor.
GATE OPEN WARNING LIGHT (COM-SIGNAL)
Signals when the gate is open, partially open or not closed completely. Turns off only when the gate is
completely closed. This signal is active during programming. N.B.: Max 3 W. If push buttons or lamps are in
excess, the control panel processes will be endangered and possibly halt operation.
OPERATION AFTER A BLACK-OUT (WITHOUT BATTERIES)
When the power supply comes back the DL1 led turns on and remains on for all the time the gate stays open.
The led will turn off only once the gate is completely closed. It is recommended to fully open the gate. Let the
gate close by itself or with automatic closing, or wait until the blinker stops flashing before commanding it to
close.
This will allow the gate to realign. If, motors were released and moved from the normal position when closed
during the blackout, the first movement after power returns must be complete.
If the black out occurs when the gate is still moving or when the gate is open and the first command sent after
the black out is a closing command, the closing of the gate will be carried out with a total delay between the two
gate leaves. Therefore, first the leaf M2 will close completely; once it is off, M1 will start closing. This separate
movement of the two gate leaves is done to avoid their incorrect overlapping.
TECHNICAL SPECIFICATIONS
- Temperature range
- Humidity
- Voltage
- Frequency
- Battery power
- Transformer Power
- Maximum absorption
- Network Micro-switches
- Maximum power gate open indicator
- Maximum blinker power
- Power available for photocells and accessories 1A ± 15%
- Power available for radio connector
0 ÷ 55 °C
<95% without condensation
230 V~ ± 10 %
50/60 Hz
20-24 Vdc
130 VA - primary 230 Vac - secondary 18 Vac
50 mA
100 ms
24 Vdc 3 W (equivalent to one 3 W or 5 LED light bulb with
resistor in series at 2.2 KΩ)
24 Vdc 20 W
200Ma