EKKO ART
A -
CONTROL PANEL FEATURES
J2
J9
J10
J8
J7
S3
B
- SETTINGS
DIP 1
(ON) - MOTOR ROTATION DIRECTION CONTROL (POINT C)
DIP 2
(ON) - TIMER (POINT D)
DIP 3
(ON) - ACTIVATES DOOR RELEASE DURING PHASES OF SLOWDOWN AND TOTAL OPENING
AND CLOSING (AS PER THE IMPACT TESTS OF EN12453)
DIP 1-2 MEMORIZATION/CANCELLATION OF RADIO CONTROL CODES FOR TOTAL OPENING
(POINT E)
DIP 1-3 MEMORIZATION/CANCELLATION OF RADIO CONTROL CODES FOR PEDESTRIAN OPENING
(POINT F)
DIP 2-1 MICRO-SWITCH CONTROLLER FOR PEDESTRIAN OPENING TIMER
DIP 4
Photocells always active (OFF) - Photocells active only during closing (ON)
DIP 5
Pre-blinking (ON) - Normal blinking (OFF)
DIP 6
Single pulse command (K BUTT) and step-by-step radio receiver (OFF) - automatic (ON)
DIP 7
Power sensor operation (ON-activated) time operation (OFF-activated).
DIP 8
Electric lock activation (ON-activated)
DIP 9
Electric lock pulse release (ON-activated)
DIP 10
Electric lock pulse engagement (ON-activated)
DIP 11
Easy release activation (ON-activated)
DIP 12
Sensor TEST activation (ON-activated).
DIP 13
Selection of 1 or 2 motor operation (default OFF 2 motors)
DIP 14
OFF EKKO ART 200D WITH ELECTRIC LOCK
ON EKKO ART 200D WITHOUT ELECTRIC LOCK
DIP 15
ON
DIP 16
IMMEDIATE CLOSING AFTER PASSING IN FRONT OF PHOTOCELLS
ON
ACTIVATED
OFF
DEACTIVATED
JP1 =>
Check that the jumper is inserted!
JP2 =>
Check that the jumper is inserted!
JP3 =>
Check that the jumper is inserted!
PROG => S3 Programming button
18
J1
F1
J3
TRANSFORMER
J4
FUSE 1
J5
J6
TR3
TR1
TR2
J1
N F
Power supply 230 Vac 50/60 Hz - external to the control
panel
J2
COM.
Common contact
CLOSE
Closing impulse contact (NA)
OPEN
Opening impulse contact (NA)
STOP
STOP impulse contact (NC)
AERIAL
Radio Antenna
J3
SIGNAL
Gate open state and battery state output indicator (24 Vdc
3 W max)
A+TEST
+ 24 Vdc safety strip self-test power supply
EDGE N.C.
Safety strip contact (NC)
COM.
Common contact
PHOTO N.C.
Photocells contact (NC)
K BUTT.
Single pulse contact (NO)
PED. BUTT.
Pedestrian opening contact (NA)
A+
+ 24 Vdc accessories power supply
A -
- 24 Vdc accessories power supply
LOCK
Electric lock connection (MAX 15 W 12 V)
- 24 Vdc blinker (code ELA1) power supply. Pay attention
to the polarity.
J4
SECONDARY
Connection to secondary coil of transformer 18 Vac
TRANSFORMER
J5
MOTOR 1
MOTOR 1 CONNECTION (without polarity)
J6
MOTOR 2
MOTOR 2 CONNECTION (without polarity)
J7
SW T2 24 V
Connector dedicated to the factory programming.
DO NOT REMOVE ANY JUMPER!
OTHERWISE THE OPERATOR WILL NOT WORK!
SW RADIO
J8
Connector dedicated to the factory programming
DO NOT REMOVE ANY JUMPER!
OTHERWISE THE OPERATOR WILL NOT WORK!
J9
RADIO
Built-in radio module
J10
BATTERY
Connector for charge card of 24 Vdc battery (code ECB4)
CHARGER
Trimmer for high speed adjustment operations
TR1
TRIMMER RUN
Trimmer for low speed adjustment operations
TRIMMER LOW SPEED
TR2
Trimmer for automatic closing time adjustment (DISABLED
TR3
TRIMMER TCA
DEFAULT AND DL6 LED OFF)
PROG
S3
Programming button
FUSE 1
T 8A
Motor protection fuse
F1
T 2A
Transformer protection fuse
ADJUSTMENTS
ATTENTION: PUT DIP 3 IN THE ON MODE ONLY AFTER HAVING CARRIED OUT ALL THE PROGRAMMING
PROCEDURES.
NOTE: WITH DIP 3 (ON) BRIEF GATE REVERSAL AFTER IMPACT IS ACTIVATED.
THIS BRIEF GATE REVERSAL PERMITS STATIC FORCE TO BE REDUCED TO ZERO WITHIN 5
SECONDS AS PER STANDARD EN12453 POINT A.2.2 (ACCEPTABLE STATIC FORCE), THEREBY
COMPLYING WITH THE IMPACT TESTS ALSO OUTLINED BY EN12453). IF COMPLIANCE WITH THE
AFOREMENTIONED STANDARD IS UNNECESSARY, SIMPLY POSITION DIP 3 TO OFF. IN THIS CASE
THE GATES STOP WITHOUT REVERSING.
RUN TRIMMER (TR1) high-speed electronic regulator
This trimmer permits motor speed adjustment (the default setting is maximum speed). Adjustment of the
automation is useful for compliance with European impact standards.
LOW-SPEED TRIMMER (TR2) Electronic slow speed approach control
The slow speed control is performed by adjusting the LOW- SPEED TRIMMER which changes the voltage
output across the motor(s) (turning it clockwise increases the speed). Adjustment is performed to determine the
correct speed at the end of opening and closing according to the gate or when there is friction that might cause
the system to function poorly.
AUTOMATIC CLOSING TRIMMER - TCA (TR3) TOTAL OR PEDESTRIAN default NOT ACTIVATED and
LED DL6 OFF (TRIMMER FULLY ROTATED COUNTERCLOCKWISE)
This trimmer makes it possible to adjust the time for total or pedestrian automatic closing. Only with gate
completely (total) or partially (pedestrian) open and LED DL6 on (trimmer rotated clockwise).
The pause time can be adjusted from a minimum of two seconds up to a maximum of two minutes.
LED SIGNALS
DL1
program activated (red)
DL2
gate opening M2 (green)
DL3
gate closing M2 (red)