Mounting and Installation
2.20
(56)
4.52
(115)
3.2
(81)
CO
Exhaust
1
CAUTION: Fasten pump securely to rack or
mounting board. Refer to Figure 4 for minimum and
maximum operating parameters. Refer to Figure 2 for
maximum height requirement and Figure 5 for a typical
initial installation.
Operation
CAUTION: Do not exceed 90 PSI (6.2 BAR) total gas
inlet pressure and liquid inlet pressure. - See Fig 4.
Inlet pressure in excess of 30 PSI requires the installa-
tion of a water pressure regulator (Flojet's 01752XXX or
01754XXX Series Water Pressure Regulator) on the fluid
inlet line, before the pump, limiting water inlet pressure
to 30 PSI (2.1 BAR). - See Fig 5.
Hose Connections
CAUTION: For product hose use food grade vinyl
hose or equivalent.
CAUTION: It is advisable to secure all hoses to
prevent excessive movement.
DANGER
ASPHYXIATION HAZARD
If used with CO
well ventilated or gas is exhausted to outside atmosphere
WARNING
EXPLOSION HAZARD
Only used with specified products. DO NOT
PUMP LIQUIDS WITH A FLASH POINT BELOW 100°F (37.8°C)
OR USE WHERE FLAMMABLE VAPORS ARE PRESENT.
4.58
(116)
Liquid
Out
2
.74
(17)
CO
2
Liquid
Inlet
In
or N
be sure the area is
2
2
via hose.
2
10 FEET
(3.05 m)
5.27
(134)
MAX
.92
(23)
1.84
(47)
3
20 PSI (1.4 BAR)
Minimum
CO
2
or
N
2
CO
Supply
2
65 PSI (4.5 BAR)
01752XXX or 01754XXX
Water Pressure Regulator
5
2
Pump Symbols
Liquid In
Oetiker
Clamp
90
15
OR
15 PSI (1.0 BAR)
Minimum
90 PSI (6.2 BAR)
Maximum
G60 Series
Pumps
30 PSI (2.1 BAR) MAX
Liquid Out
4
120°F (49°C)
Safe Fluid
Operating
Temperature
34°F (1.1°C)