Remedy of faults
Attention! Dangerous electrical voltage.
Possible consequences: Death or severe injury.
Protective measures: Isolate the unit prior to reaching into the water and carrying out any work on the unit.
Secure the unit from being switched on inadvertantly.
Malfunction
Pump does not start
Pump switches off after a short running period
Irregular water image effect, loud flow noise
Irregular 'water' picture, picture fluctuates nota-
bly
Switch on the unit
MIDI Floating Fountain LM, 230 V: Allow the unit to cool down (approx. 30 seconds), then press the button (38) at the
control box (35). Pump will start.
MIDI Floating Fountain LM, 400 V: Press the green button (41) at the motor (overload) protection switch (36). Pump
will start.
Cleaning
Attention! Dangerous electrical voltage.
Possible consequences: Death or severe injury.
Protective measures: Isolate the unit prior to reaching into the water and carrying out any work on the unit.
Secure the unit from being switched on inadvertantly.
If necessary, clean the unit with clear water using a soft brush.
Storage/Over-wintering
Remove the unit at temperatures below zero degrees centigrade. Thoroughly clean and check the unit for damage.
Disposal
Do not dispose of this unit with domestic waste! For disposal purposes, please use the return system provided.
Disable the unit beforehand by cutting off the cables.
16
Cause
No mains voltage
Filter basket soiled
Motor defective
Pump overloaded due to heavily soiled water
Water temperature too high
Pump overloaded because the filter basket is
soiled
Motor defective
Motor (overload) protection switch (CEE) incor-
rectly set
Filter basket soiled
The float body moves
The 'water' picture is affected by strong wind
Remedy
Check the mains voltage and the supply lines
Clean the filter basket under running water
using a brush
Contact OASE
 Improve the water quality to enhance the
pump's operating life
 Clean the filter basket under running water
using a brush
Only operate the unit at the water temperature
specified in the technical data
Clean the filter basket under running water
using a brush
Contact OASE
Have the switch checked and adjusted by a
qualified electrician
Clean the filter basket under running water
using a brush
Check the float body fastening
Fit a wind gauge with switch-off function