table instead of the cable supplied with the device. Use the connection bridges supplied
with the device. To access the terminal block, remove the cover by lifting it off with a
flathead screwdriver.
Remember that the connecting wire must match the type of connection and the power rating
of the stove.
Do not solder the cable ends. The cable sheath must be mounted in the strain relief device,
which is suitable for cables with a diameter of 7 to 15 mm.
NOTE
Ensure you connect the earth connection to the cooker's
terminal, indicated by the
supply must be fitted with an emergency stop circuit breaker,
which allows the electrical supply to be shut off at any time.
There must be a minimum distance of 3 mm between the
emergency stop breaker contacts.
Before plugging the cooker into the electrical system, check the information provided on the
serial panel and in the connection diagram.
NOTE
• The installer is required to provide the user with the
«Electrical Connection Certificate of the appliance ».
• Connecting the unit in a manner other than that shown
on the wiring diagram may damage the unit.