The bar at the top left fl ashes to indicate
that the grease fi lter is saturated.
The bar at the top right fl ashes to indicate
that the odour fi lter is saturated.
If both bars are fl ashing, then both fi lters
are saturated.
You must then clean/replace the grease fi lter (A) or odour
fi lter (B) or both, accordingly (see "Maintenance and care").
The latter only applies to the fi lter version.
To reset the fi lter counter:
Hold down T4 for three seconds while the hood is on.
If both fi lter warnings are active at the same time, you must
reset each separately. The fi rst sequence resets the grease
fi lter, while the second sequence resets the odour fi lter.
Confi guring the hood
To set the operating mode of the hood, hold down T4 for 6
seconds while the product is off. After a long beep, the type
of installation displays:
Ducted
(square at bottom left fl ashing).
Filter
(square at bottom right fl ashing).
You can change the type of installation by pressing T4. To
quit confi guration mode, press T1 once; this switches the
unit off and saves the last displayed setting.
Maintenance and care
Caution! Before cleaning or servicing the unit,
disconnect it from the mains by pulling the power plug
or disconnecting the main circuit breaker.
First cleaning
• Remove the protective fi lm
• Clean with a damp sponge and a little neutral soap
• Rinse off with a damp cloth
• Dry with a soft cloth; if the hood is stainless steel, dry
along the metal's grain
All manuals and user guides at all-guides.com
Periodic cleaning
The hood must be cleaned frequently (at least as often as
you service the grease fi lter), inside and out. Use a damp
cloth and a neutral liquid detergent with lukewarm water.
Do not use abrasive or corrosive products.
Warning: Failure to observe the hood cleaning and fi lter
cleaning/replacement instructions can result in fi res. Follow
the instructions carefully. The manufacturer is not liable for
any damage to the motor or fi res caused by incorrect care
or failure to follow the above instructions.
Servicing the grease fi lter (A)
If washed in a dishwasher, the metal fi lter may change
colour, but this does not affect its performance.
Servicing the charcoal fi lter (B)
The charcoal fi lter retains unpleasant cooking odours.
The fi lter saturates after a variable time, depending on the
type of cooking and how often the grease fi lter is cleaned.
The cartridge must be replaced at least once every twenty
months.
This fi lter can NOT be washed or regenerated
The grease fi lter retains the
particles of grease produced
during cooking; it must be
cleaned at least once a month
w i t h a n o n - a g g r e s s i v e
detergent, either by hand or
A
with a low temperature, short
dishwasher cycle.
To extract the grease fi lter,
pull the spring loaded handle.
Disassembly: Remove the
activated-carbon filter by
pressing the two front levers
B
which secure it to the hood.
A s s e m b l y : S e c u r e t h e
activated-carbon fi lter fi rst in
the back using the hood's
metal tabs and then in the
front by pressing the two
levers.
B
GB
37