SEAL ALL DUCT JOINTS
• Using the openings in the rear panel, wrap UL listed
aluminum foil tape around all internal duct joints and
the elbow.
UL listed aluminum
foil tape
WARNING
Replace the rear heater cover.
Close the back opening with exhaust cover
plate.
Failure to do so may result in fire or electrical
shock.
INSTALL EXHAUST COVER
PLATE AND COMPLETE
EXHAUST SYSTEM
• Add the exhaust cover plate to the duct opening on
rear panel.
Exhaust cover plate
NEVER LEAVE THE BACK OPENING WITHOUT
THE PLATE
• Connect standard metal elbows and ducts to complete
the exhaust system.
• Place dryer in final location.
• Secure the dryer duct to the house venting by adding
UL listed aluminum foil tape or clamp duct.
Printed in USA
Installation Instructions
UL listed
DUCT
aluminum foil
TAPE
tape
- Fire Hazard
CONNECTING THE DRYER TO
HOUSE VENT
RIGID METAL TRANSITION DUCT
• For best drying performance, a rigid metal transition
duct is recommended.
• Rigid metal transition ducts reduce the risk of
crushing and kinking.
UL-LISTED FLEXIBLE METAL CLOTHES
DRYER TRANSITION DUCT
• If rigid metal cannot be used, then UL-listed flexible
metal clothes dryer transition duct (GE Appliances
part – PM08X10085) can be used.
• Never install transition duct in walls, ceilings, floors
or other enclosed spaces.
• Total length of transition duct should not exceed 8'
(2.4 m).
• For many applications, installing elbows at both
the dryer and the wall is highly recommended (see
illustrations in next section). Elbows allow the dryer
to sit close to the wall without kinking and/or crushing
the transition duct, maximizing drying performance.
• Avoid resting the duct on sharp objects.
UL-LISTED FLEXIBLE METAL (FOIL-TYPE)
TRANSITION DUCT
• In special installations, it may be necessary to
connect the dryer to the home exhaust vent
using flexible metal (foil-type) transition duct. UL–
LISTED universal flexible dryer transition duct
(GE Appliances parts – PM8X73 or WX8X73)
may be used ONLY in installations where rigid
metal or flexible metal transition ducting cannot
be used AND where a 4" (10.2 cm) diameter can
be maintained throughout the entire length of the
transition duct.
• In Canada and the United States, only transition
ducts that comply with "UL 2158A STANDARD
FOR CLOTHES DRYER TRANSITION DUCT"
shall be used.
• Avoid resting the duct on sharp objects.
• For best drying performance:
1. Slide one end of the duct over the clothes
dryer outlet pipe.
2. Secure the duct with a clamp.
3. With the dryer in its permanent position,
extend the duct to its full length. Allow 2" (5.08
cm) of duct to overlap the exhaust pipe. Cut
off and remove excess duct. Keep the duct as
straight as possible for maximum airflow.
4. Secure the duct to the exhaust pipe with the
other clamp.
4