1.0 general information
When the appliance is installed at elevations above 4,500ft (1372m), and in the absence of specific recommendations
from the local authority having jurisdiction, the certified high altitude input rating shall be reduced at the rate of 4% for each
additional 1,000ft (305m). Expansion / contraction noises during heating up and cooling down cycles are normal
and are to be expected. Change in flame appearance from "HI" to "LO" is more evident in natural gas than in
propane.
This appliance is approved for bathroom, bedroom and bed-sitting room installations and is certified for mobile
home installation.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not
convertible for use with other gases, unless a certified kit is used.
note:
A barrier designed to reduce the risk of burns from the hot viewing glass is provided with the appliance and
must be installed.
The protective wrap on plated parts is best removed when the assembly is at room temperature but this can be
improved if the assembly is warmed, using a hair dryer or similar heat source.
Vented decorative gas appliance: not a source of heat; not for use with solid fuel.
Batteries must be disposed of according to the local laws and regulations. Some batteries may be
recycled, and may be accepted for disposal at your local recycling center. Check with your
municipality for recycling instructions.
1.1
rates and efficiencies
Fuel Type
Altitude (FT)
Les piles doivent être mises au rebut conformément aux lois et à la réglementation locales.
Max. Input (BTU/hr)
Certaines piles peuvent être recyclées et acceptées dans votre centre de recyclage local. Rensei-
Min. Inlet Gas Supply Pressure
gnez-vous auprès de votre municipalité au sujet des directives de recyclage.
Max. Inlet Gas Supply Pressure
Manifold Pressure (Under Flow Conditions)
* Max. inlet pressure not to exceed 13".
Las baterías deben desecharse de acuerdo con las leyes y regulaciones locales. Algunas baterías
pueden reciclarse, y es posible que su centro de reciclado local las acepte para desecharlas.
Consulte en su municipalidad sobre las instrucciones para el reciclado.
Installer, please fill out the following information:
Propane:
standard checklist
TB36PTR
TB36PTRE
TB36PTR-PBR
Natural Gas
0-4,500
18,000
4.5" w.c. (11mb)
7"* w.c. (17mb)
3.5" w.c. (9mb)
Propane
11" w.c. (27mb)
13" w.c. (32mb)
10" w.c. (25mb)