Télécharger Imprimer la page

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

NATURAL GAS MODELS:
PROPANE GAS MODELS:
SAFETY INFORMATION
WARNING
!
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly
could result in serious injury, death, or
property damage.
- Do not store or use gasoline or other
fl ammable vapors and liquids in the vicinity of
this or any other appliance.
- WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not
use any phone in your building.
Immediately call your gas supplier from a
neighbour's phone. Follow the gas
supplier's instructions.
If you cannot reach your gas supplier, call
the fi re department.
- Installation and service must be
performed by a qualifi ed installer, service
agency, or the supplier.
This appliance may be installed in an aftermarket,
permanently located, manufactured home (USA
only) or mobile home, where not prohibited by
local codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is
not convertible for use with other gases, unless
a certifi ed kit is used.
INSTALLER:
Leave this manual with the appliance
CONSUMER:
Retain this manual for future reference
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada / 103 Miller Drive, Crittenden, Kentucky, USA, 41030
Phone 1 (866) 820-8686 • www.timberwolffi replaces.com • ask@timberwolffi replaces.com
$10.00
TB36NTR / TB36NTRE
ADD PRODUCT CODE HERE (TRADE GOTHIC LT STD FONT)
TB36PTR / TB36PTRE
INSTALLATION AND
ADD MANUAL TITLE
OPERATION MANUAL
CERTIFIED TO THE CANADIAN AND AMERICAN NATIONAL STANDARDS:
CSA 2.22 AND ANSI Z21.50 FOR VENTED DECORATIVE GAS APPLIANCES
IF INSTALLATION + OPERATION, ADD SERIAL
CSA /
INTERTEK
BARCODE LABEL ON THE OWNER'S MANUAL"
LOGO
Product Name / Code
(MUST use title from Price Book)
ADD ____ ILLUSTRATED
ADD PRODUCT IMAGE
FOR INDOOR USE ONLY
NUMBER LABEL HERE
IF SEPARATE MANUALS, ADD "PLACE
ENGLISH
FRENCH PG. 77
TB36
W415-2881 / C / 03.07.22

Publicité

loading

Sommaire des Matières pour Timberwolf TB36 Serie

  • Page 1 TB36NTR / TB36NTRE ADD PRODUCT CODE HERE (TRADE GOTHIC LT STD FONT) NATURAL GAS MODELS: ENGLISH TB36PTR / TB36PTRE PROPANE GAS MODELS: FRENCH PG. 77 INSTALLATION AND ADD MANUAL TITLE OPERATION MANUAL TB36 Product Name / Code SAFETY INFORMATION (MUST use title from Price Book) WARNING ADD ____ ILLUSTRATED FIRE OR EXPLOSION HAZARD...
  • Page 2 safety information WARNING DANGER • This appliance is hot when operated and can cause severe burns if contacted. • Any changes or alterations to this appliance or its controls can be dangerous and is prohibited. HOT GLASS WILL CAUSE • Do not operate appliance before reading and BURNS.
  • Page 3 patterns. RAAK HET GLAS NIET AAN TOT HET IS AFGEKOELD. DUTCH safety information LAAT KINDEREN NOOIT HET GLAS AANRAKEN. WARNING Dit apparaat is voorzien van een barrière die is ontworpen om het risico van brandwonden door het hete kijkglas te beperken. Deze barrière moet worden geïnstalleerd ter bescherming van kinderen •...
  • Page 4 table of contents general information electrical information rates and efficiencies electronic wiring diagram installation checklist battery back-up installation gas installation installation overview operation (electronic) rating plate information mobile home installation pilot-on-demand operation (millivolt) dimensions venting requirements finish framing typical vent installation minimum framing dimensions 49 10.0 finishing...
  • Page 5 standard checklist Installer, please fill out the following information: Customer: Address: Date of Installation: Location of appliance: Installer: Dealer/Distributor contact number: Serial #: Model: Natural Gas: TB36NTR Propane: TB36PTR TB36NTRE TB36PTRE TB36NTR-PBR TB36PTR-PBR 1.0 general information When the appliance is installed at elevations above 4,500ft (1372m), and in the absence of specific recommendations from the local authority having jurisdiction, the certified high altitude input rating shall be reduced at the rate of 4% for each additional 1,000ft (305m).
  • Page 6 general information installation checklist GAS FIREPLACE INSTALLATION CHECKLIST Customer: Date Installed: Address: Installer: Model: Dealer: Serial #: Dealer Phone #: This checklist is a reference tool only. It is not intended as a substitute for the installation instructions. Fireplace Installation IF NOT, PLEASE EXPLAIN WHY? Is the fireplace level and secured? Are the factory supplied non-combustible materials installed?
  • Page 7 general information installation overview Recommended installation steps: 1. Determine venting requirements before deciding the final location of the appliance. 2. Install rough framing (see “rough framing” section). 3. Place the appliance in its final position. 4. Install appliance venting (see “venting installation” section). 5.
  • Page 8 general information WARNING • Always light the pilot whether for the first time or if the gas supply has run out, with the glass door opened or removed. • Provide adequate clearance for servicing and operating the appliance. • Provide adequate ventilation. •...
  • Page 9 general information rating plate information Certified to Canadian and American National Standards: CSA 2.22-XXXX / ANSI Z21.50-XXXX for Vented Decorative Gas Appliances Certifié selon les normes Nationales Canadiennes et Américaines: CSA 2.22-XXXX / ANSI Z21.50-XXXX pour les Appareils à gaz décoratif à évacuation Direct vent, vented gas fireplaces.
  • Page 10 general information dimensions W415-2881 / C / 03.07.22...
  • Page 11 2.0 venting requirements venting requirements WARNING • Risk of fi re. Maintain specifi ed air space clearances to vent pipe and appliance. • The vent system must be supported every 3’(0.9m) for both vertical and horizontal runs. Use support ring assembly W010- 0067 or equivalent non-combustible strapping to maintain the minimum clearance to combustibles for both vertical and horizontal runs.
  • Page 12 For optimum fl ame appearance and appliance performance, keep the vent length and number of elbows to a minimum. venting requirements The air terminal must remain unobstructed at all times. Examine the air terminal at least once a year to verify that it is unobstructed and undamaged.
  • Page 13 venting requirements 16" (40.6cm) minimum 40 ft (12m) maximum 3 ft (1m) minimum 20" (50.8cm) 24" (61cm) 24" minimum plus rise * (61cm) REAR VENT * See "venting" section W415-2881 / C / 03.07.22...
  • Page 14 venting requirements special vent installations 2.2.1 periscope termination Use the periscope kit to locate the air termination above grade. The periscope must be installed so that when fi nal grading is completed, the bottom air slot is located a minimum 12” (305mm) above grade. The maximum allowable vent length (including both rise and run) is 10’...
  • Page 15 venting requirements minimum air terminal location clearances Covered balcony applications ††* = 3 feet ≤ 15 feet = 2 x ACTUAL (0.9m) (4.6m) note: INSTALLATIONS Wall terminals are for illustration purposes only. Size and shapes may vary. Wall terminal CANADA U.S.A.
  • Page 16 venting requirements venting application flow chart TOP EXIT Horizontal Termination Vertical Termination Vertical rise is equal Vertical rise is equal Vertical rise is less Vertical rise is less to or greater than to or greater than than horizontal run than horizontal run the horizontal run the horizontal run Horizontal run +...
  • Page 17 venting requirements definitions For the following symbols used in the venting calculations and examples are: > - greater than > - equal to or greater than < - less than < - equal to or less than - total of both horizontal vent lengths (Hr) and offsets (Ho) in feet - combined horizontal vent lengths in feet - offset factor: .03 (total degrees of offset - 90°*) in feet - combined vertical vent lengths in feet...
  • Page 18 venting requirements top exit horizontal termination ) < (V See graph to determine the required vertical Simple venting confi guration (only one 90° elbow) rise V for the required horizontal run H 40 (12.2) 40 (12.2) 39 (11.9) 40 (12.2) 39 (11.9) 39 (11.9) REQUIRED...
  • Page 19 venting requirements ) > (V Simple venting configuration See graph to determine the required vertical rise V for the required horizontal run H (only one 90° elbow) 150 (381) 147 (373) REQUIRED VERTICAL 100 (254) RISE IN INCHES (CENTIMETERS) V 57 (145) 50 (127) 8 (20.3)
  • Page 20 venting requirements rear exit horizontal termination ) < (V Simple venting configuration See graph to determine the required vertical rise V for the required (only two 90° elbows) horizontal run H 40 (12.2) 35.3 (10.7) REQUIRED 30 (9.1) VERTICAL RISE IN 20 (6.1) FEET (METERS) V...
  • Page 21 venting requirements ) > (V Simple venting configuration See graph to determine the required vertical rise V for the (only two 90° elbows) required horizontal run H 12.5 (3.8) 12.25 (3.7) REQUIRED VERTICAL RISE IN 8.3 (2.54) FEET (METERS)V (1.68) 4.2 (1.3) (0.3) 12.5...
  • Page 22 venting requirements top and rear exit vertical termination ) < (V See graph to determine the required vertical rise V for the Simple venting configurations. required horizontal run H 40 (12.2) 30 (9.1) REQUIRED VERTICAL RISE IN FEET 20 (6.1) (METERS)V 10 (3.1) 3 (0.9)
  • Page 23 venting requirements ) > (V See graph to determine the required vertical rise V for the Simple venting configurations. required horizontal run H 20 (6.1) 19 (5.8) REQUIRED VERTICAL 10 (3.1) RISE IN FEET 3 (0.9) (METERS)V (1.5) (3.1) (4.6) (6.1) (7.6) (9.1)
  • Page 24 venting requirements Example: = 1.5 FT (0.5m) = 5 FT (1.5m) = 1.5FT (0.5m)+ 5FT (1.5m) = 6.5 FT (2m) = 1 FT (0.3m) = 1 FT (0.3m) = 10.75 FT (3.3m) = 1FT (0.3m) + 1FT (0.3m) + 10.75FT (3.3m) = 12.75FT (3.9m) = .03 (three 90°...
  • Page 25 venting requirements 2.11 rear exit shield (for rear vent only) Remove the safety barrier assembly and door from the appliance (see “safety barrier & door removal / installation” section). Loosen the two screws that secure the exhaust plate, and slide the shield in place by sliding its slotted openings behind the screwheads.
  • Page 26 venting requirements 2.12 top exit WARNING • Failure to install the cover plate and gasket will cause the appliance to function improperly and can cause injury or property damage. Remove the safety barrier and glass door (see "safety barrier & door removal/installation" section). Remove the contents from the firebox and set aside.
  • Page 27 rough framing 3.0 rough framing note: When using optional fi nishing accessories, the framing dimensions and fi nishing materials may differ from what is outlined in the section below; refer to the leafl et instructions supplied in the accessory kit for specifi c framing and fi nishing specifi cations.
  • Page 28 rough framing minimum framing dimensions HORIZONTAL VENT SECTIONS: A minimum of 1" (25mm) at the bottom and sides, and 3" (76.2mm) at the top of the vent pipe on all horizontal runs to combustibles is required. note: The minimum clearances from the top of the horizontal vent pipe to combustible materials may be reduced from 3"...
  • Page 29 rough framing minimum enclosure clearances TOP VENT PLAFOND CEILING ENCLOSURE TOP EXIT ENCLOSURE The appliance requires a minimum enclosure height of 50 1/2" (128.3cm). For temperature requirements, the enclosure space around and above the appliance must be left unobstructed. note: The vent shield is telescopic and must be adjusted to shield the full depth of the combustible wall penetration.
  • Page 30 rough framing MINIMUM REAR VENT CLEARANCES For rear vent termination not exceeding 10" (254mm) of horizontal vent run. Ceiling Enclosure REAR EXIT ENCLOSURE The appliance requires a minimum enclosure height of 41" (104.1cm). For temperature requirements, the enclosure space around and above the appliance must be left unobstructed. note: The vent shield is telescopic and must be adjusted to shield the full depth of the combustible wall penetration.
  • Page 31 rough framing MAXIMUM REAR VENT CLEARANCES (EXAMPLE 1: INTERIOR NICHE / BUMPOUT / ALCOVE) Ceiling REAR EXIT ENCLOSURE The appliance requires a minimum enclosure height of 41" (104.1cm). For temperature requirements, the enclosure space around and above the appliance must be left unobstructed. note: The vent shield is telescopic and must be adjusted to shield the full depth of the combustible wall penetration.
  • Page 32 rough framing MAXIMUM REAR VENT CLEARANCES (EXAMPLE 2: EXTERIOR ALCOVE / DOGHOUSE) REAR EXIT ENCLOSURE The appliance requires a minimum enclosure height of 41" (104.1cm). For temperature requirements, the enclosure space around and above the appliance must be left unobstructed. note: The vent shield is telescopic and must be adjusted to shield the full depth of the combustible wall penetration.
  • Page 33 rough framing note: For heavier finishing materials such as marble, we recommend adding extra support to the frame. Ensure there is adequate floor support for the appliance and finishing material. Before framing your appliance, determine vent requirements before deciding the final location of the appliance. After rough framing, place the appliance in its final position.
  • Page 34 4.0 venting installation venting installation WARNING • Ensure to unpack all loose materials from inside the fi rebox prior to connecting the gas and electrical supply • If your appliance is supplied with a remote, ensure the remote receiver is in the “OFF” position prior to connecting the gas and electrical supply to the appliance.
  • Page 35 venting installation horizontal installation WARNING • The fi restop assembly must be installed with the vent shield to the top. • Terminals must not be recessed into a wall or siding more than the depth of the return fl ange of the mounting plate.
  • Page 36 venting installation vertical installation This application occurs when venting through a roof. Installation kits for various roof pitches are available from your authorized dealer / distributor. See the “accessories” section to order specifi c kits required. A. Determine the air terminal location, cut and frame a square opening, as illustrated, in the ceiling and the roof to provide the minimum 1"...
  • Page 37 venting installation using either flexible or rigid vent components WARNING • Do not allow the inner fl ex pipe to bunch up on horizontal or vertical runs and elbows. Keep it pulled tight. • Spacers are attached to the inner fl ex pipe at predetermined intervals to maintain an even air gap to the outer fl ex pipe.
  • Page 38 venting installation 4.3.2 vertical air terminal installation WARNING • Maintain a minimum 2” (51mm) space between the air inlet base and the storm collar. note: Fastening hardware provided with appropriate roof terminal and liner kits. Fasten the roof support to the roof using 6 screws. The roof support is optional.
  • Page 39 venting installation 4.3.4 horizontal air terminal installation Move the appliance into position. Measure #10x2" the vent length required between terminal and SCREWS appliance taking into account the additional CAULKING length needed for the fi nished wall surface and any 2” (50.8mm) overlaps between venting INNER components.
  • Page 40 venting installation 4.3.5 vertical air terminal installation WARNING • Maintain a minimum 2” (51mm) space between the air inlet base and the storm collar. note: Fastening hardware provided with appropriate roof terminal and liner kits. Before attaching elbows to the collars on the back of the appliance, 1 1/2” (38.1mm) will need to be trimmed off the 4”...
  • Page 41 venting installation vertical through existing chimney WARNING • Risk of fi re. • Co-axial to co-linear venting confi gurations must only be used in a non-combustible chimney or enclosure. Installation in a combustible enclosure could result in a fi re. This appliance is designed to be attached to a 3”...
  • Page 42 venting installation 4.4.1 restricting vertical vents WARNING • Turn off gas and electrical supply before servicing the appliance. • Appliance may be hot. Do not service until appliance is cool. • For safe and proper operation of the appliance, follow the venting instructions exactly. •...
  • Page 43 venting installation 5.0 electrical information electronic wiring diagram WARNING • Do not wire 110 volts to the valve or wall switch. (where applicable) GREEN ON / OFF ORANGE SWITCH TRANSFORMER IPI / CPI ON / OFF BATTERY HOUSING ELECTRONIC DISCONNECT THESE VALVE CONNECTIONS TO THE ON/OFF SWITCH.
  • Page 44 electrical information battery back-up installation WARNING • Ensure the gas and electrical power to the appliance is turned off. • Appliance may be hot. Do not service until the appliance has cooled. note: In the event of a power failure, your appliance can be operated using the battery back-up supplied. Remove the safety barrier by lifting it up and off of the four shoulder screws.
  • Page 45 6.0 gas installation gas installation WARNING • Risk of fi re, explosion, or asphyxiation. Ensure there are no ignition sources such as sparks or open fl ames. • Support gas control when attaching gas supply pipe to prevent damaging gas line. •...
  • Page 46 7.0 operation (electronic) operation (electronic) WARNING • If you do not follow these instructions exactly, a fi re or explosion may result causing property damage, personal injury, or loss of life. • If applicable, always light the pilot whether for the fi rst time or if the gas supply has run out with the glass door opened or removed.
  • Page 47 B. Turn off the remote wall switch to the appliance. C. Turn off all electric power to the appliance if service is to be performed. D. Turn manual shutoff valve clockwise to the “OFF” positon. Do not force. operation (electronic) ADD TITLE: PILOT-ON-DEMAND pilot-on-demand This appliance is equipped with an “On Demand”...
  • Page 48 8.0 operation (millivolt) operation (electronic) WARNING • If you do not follow these instructions exactly, a fi re or explosion may result causing property damage, personal injury, or loss of life. • If applicable, always light the pilot whether for the fi rst time or if the gas supply has run out with the glass door opened or removed.
  • Page 49 9.0 finish framing finish framing minimum framing dimensions 35" 88.9cm 16" 40.6cm FRENCH W415-2881 / C / 03.07.22...
  • Page 50 10.0 finishing finishing WARNING • Risk of fire! • Never obstruct the front opening of the appliance. • Do not strike, slam, or scratch. Do not operate appliance with glass removed, cracked, or scratched. • Facing and/or finishing material must never overhang into the appliance opening. •...
  • Page 51 finishing 10.2 front hood installation note: This hood must be installed, if it has not already been factory installed. Safety door and barrier must be removed. Remove the securing screws from the top of the firebox, as shown. Install the front hood, ensuring it is angled downward when installed. Reinstall the previously removed securing screws.
  • Page 52 finishing 10.3 non-combustible facing material WARNING Non-combustible facing material must not project more than 4” (101.6mm) from the face of the door (all four sides). If greater projections are desired, increase the clearance to the sides, bottom and top by 2” (50.8mm) for every additional 1”...
  • Page 53 finishing 10.4 minimum mantel clearances WARNING • Risk of fi re. Maintain all specifi ed air space clearances to combustibles. Failure to comply with these instructions may cause a fi re or cause the appliance to overheat. Ensure all clearances (i.e. back, side, top, vent, mantel, front, etc.) are clearly maintained.
  • Page 54 finishing 10.5 recessed installation WARNING • Installing a television or other electronics above the appliance may cause discolouration, melting, or damage to the electronics. Use clearances as guidelines and refer to your TV manufacturer’s instructions for further information Image note: Recesses or alcoves above the appliance must be made with non-combustible material and regular minimum clearances, as defi ned for combustible materials, must still be applied.
  • Page 55 If applicable, insert the following statement: “PHAZER™ logs [and glowing embers], exclusive to Napoleon/Continental, provide a unique and realistic PHAZER™ logs and glowing embers, exclusive to Timberwolf, provide a unique and realistic glowing effect that is If applicable, insert the following statement: glowing effect that is different in every installation.
  • Page 56 Stud Stud Tray Tray Tray Edge Tray Edge (Log #5) (Log #5) Media Media Media Media finishing Tray Tray Edge Tray Tray Edge Holes under log Holes under log (not illustrated). (not illustrated). Holes under log Holes under log (not illustrated). (not illustrated).
  • Page 57 NOTE: ENSURE NOMENCLATURE IS NOTE: ENSURE NOMENCLATURE IS CONSISTENT THROUGHOUT. CONSISTENT THROUGHOUT. finishing IF SPACE IS LEFT OVER, USE THIS BOX TO IF SPACE IS LEFT OVER, USE THIS BOX TO SHOW CORRECT FINAL LOG PLACEMENT SHOW CORRECT FINAL LOG WITH LINE DRAWINGS.
  • Page 58 finishing 10.7 glowing embers WARNING • Completely blocking the burner ports can cause an incorrect fl ame pattern, carbon deposits and delayed ignition. Tear the embers into pieces and loosely layer above the burner ports covering the burner area. Care should be taken to shred the embers into thin, small irregular pieces as only the exposed edges of the fi bre hairs will glow.
  • Page 59 11.0 optional blower installation WARNING • Ensure the appliance is completely cool before starting installation. • To avoid danger of suffocation, keep the packaging bag away from babies and children. Do not use in cribs, aub - aSCent univerSal blower inStallation inStruCtionS beds, carriages, or play pens.
  • Page 60 (9.5mm - 12.7mm) (9.5mm - 12.7mm) Flame must envelop La flamme doit envelopper upper la thermocouple de 3/8" à adjustment 12.0 adjustment 3/8" to 1/2" SIT ELECTRONIC IGNITION 1/2" (12.7mm - 9.5mm) of (9.5mm - 12.7mm) thermocouple 12.1 pilot burner adjustment 3/8”...
  • Page 61 adjustment SIT ELECTRONIC IGNITION 12.3 flame characteristics 3/8” - 1/2” (9.5mm - 12.7mm) It’s important to periodically perform a visual check of the pilot and burner flames. Compare them to the ADD IMAGE Flame must envelop illustration provided. If any flames appear abnormal, upper call a service person.
  • Page 62 13.0 maintenance maintenance WARNING • Turn off the gas and electrical power before servicing the appliance. • Appliance may be hot. Do not service until appliance has cooled. • Do not use abrasive cleaners on glass. • Do not paint the pilot assembly. This appliance and its venting system should be inspected before use and at least annually by a qualifi ed service person.
  • Page 63 maintenance 13.1 annual maintenance WARNING • Annual maintenance should be performed by a qualifi ed service technician • The fi rebox becomes very hot during operation. Let the appliance cool completely or wear heat resistant gloves before conducting service. • Never vacuum hot embers.
  • Page 64 maintenance 13.2 door glass replacement WARNING • Do not use substitute materials. • Glass may be hot. Do not touch glass until cooled. • Care must be taken when removing and disposing of any broken door glass or damaged components. Be sure to vacuum up any broken glass from inside appliance before operation.
  • Page 65 replacements 14.0 replacement parts WARNING • Failure to position the parts in accordance with this manual or failure to use only parts specifi cally approved with this appliance may result in property damage or personal injury. Contact your dealer for questions concerning prices and policies on replacement parts. Normally, all parts can be ordered through your Authorized dealer / distributor.
  • Page 66 replacement parts W415-2881 / C / 03.07.22...
  • Page 67 replacement parts W415-2881 / C / 03.07.22...
  • Page 68 replacement parts W415-2881 / C / 03.07.22...
  • Page 69 15.0 accessories W415-2881 / C / 03.07.22...
  • Page 70 16.0 troubleshooting (electronic) troubleshooting WARNING • Always light the pilot whether for the fi rst time or if the gas supply has run out, with the glass door open or removed. • Turn off gas and electrical power before servicing the appliance. •...
  • Page 71 Check that venting is installed correctly. appliances). Room is in negative pressure; increase fresh air supply. troubleshooting (electronic) symptom problem test solution Pilot will not light. Makes Wiring: short, loose, or damaged Verify the thermocouple/sensor is clean and the wiring is undamaged. Verify the interrupter block is not damaged or too tight.
  • Page 72 Wire connector pins are bent. Straighten pins. symptom problem test solution Valve wiring is damaged. Replace valve. troubleshooting (electronic) Lights or blower Control module switch in Verify ON/OFF switch is in the “I” position which denotes on. won’t function (if wrong position.
  • Page 73 17.0 troubleshooting (millivolt) WARNING • Always light the pilot whether for the fi rst time or if the gas supply has run out, with the glass door open or removed. • Turn off gas and electrical power before servicing the appliance. •...
  • Page 74 (9.5mm - 12.7mm) (9.5mm - 12.7mm) Flame must envelop La flamme doit envelopper upper la thermocouple de 3/8" à 3/8" to 1/2" troubleshooting (millivolt) 1/2" (12.7mm - 9.5mm) of (9.5mm - 12.7mm) thermocouple symptom problem test solution Pilot will not light. No spark at pilot burner.
  • Page 75 Timberwolf® neither assumes, nor authorizes any third party to assume, on its behalf, any other liabilities with respect to the sale of this product. Timberwolf® will not be responsible for: over- fi ring, downdrafts, spillage caused by environmental conditions such as rooftops, buildings, nearby trees, hills, mountains, inadequate vents or ventilation, excessive venting confi gurations, insuffi cient makeup air, or negative air pressures which may or may not be caused by mechanical systems such as exhaust fans, furnaces, clothes dryers, etc.
  • Page 76 Produced and distributed by: 24 Napoleon Road, Barrie, Ontario, Canada L4M 0G8 Tel: 1-866-820-8686 timberwolffireplaces.com...
  • Page 77 TB36NTR / TB36NTRE MODÈLES DE GAZ NATUREL ADD PRODUCT CODE HERE (TRADE GOTHIC LT STD FONT) TB36PTR / TB36PTRE MODÈLES DE PROPANE FRANÇAIS FRANÇAIS MANUEL D'INSTALLATION ADD MANUAL TITLE ET D'OPÉRATION TB36 Product Name / Code CONSIGNES DE SÉCURITÉ (MUST use title from Price Book) AVERTISSEMENT ADD ____ ILLUSTRATED RISQUE D’INCENDIE OU D’EXPLOSION...
  • Page 78 NEVER ALLOW CHILDREN TO TOUCH GLASS. A barrier designed to reduce the risk of burns from the hot consignes de sécurité viewing glass is provided with this appliance and must be installed for the protection of children and other at-risk AVERTISSEMENT individuals.
  • Page 79 continue de s’éteindre, faire réparer. Garder propres le brûleur et le compartiment de contrôle. • Cet appareil ne devra être modifi é en aucun cas. • Ne laissez pas les ventilateurs souffl er directement sur l’appareil. Empêchez les courants d’air de modifi er consignes de sécurité...
  • Page 80 table des matières information électrique information générale schéma de câblage électronique taux et efficacités vérification d’installation installation du sauvegarde de pile branchement du gaz vue d'ensemble d'installation information à propos de la plaque opération (électronique) veilleuse sur demande d’homologation opération (millivolt) installation dans une maison mobile 85 dimensions encadrement fini...
  • Page 81 liste de vérification Installateur, veuillez rempli les informations suivants: Client: Adresse: Date d’installation: Location de l’appareil: Installateur: Numéro de contact du détaillant / distributeur: # de série: Modèle: TB36NTR TB36PTR Gaz Naturel: Propane: TB36NTRE TB36PTRE TB36NTR-PBR TB36PTR-PBR 1.0 information générale Lorsque l’appareil est installé...
  • Page 82 information générale vérification d’installation LISTE DE VÉRIFICATION POUR L'INSTALLATION D'UN FOYER AU GAZ Client : Date d'installation : Adresse : Installateur : Modèle : Détaillant : N° de série : Téléphone : Cette liste de vérification est fournie uniquement à titre de référence. Elle n'est pas destinée à remplacer les instructions d'installation.
  • Page 83 information générale vue d'ensemble d'installation Étapes d'installation recommandées: 1. Determinez les exigences d'évacuation avant de determinez le position finale de l'appareil. 2. Installez l'encadrement approximatif (voir la section « encadrement approximatif »). 3. Placez l'appareil dans le position finale. 4. Installez l'évacuation de l'appareil (voir la section « installation d'évacuation »). 5.
  • Page 84 information générale AVERTISSEMENT • Allumez toujours la veilleuse, que ce soit pour la première fois ou lorsque l’approvisionnement en gaz est épuisé, avec la porte vitrée ouverte ou retirée. • Prévoyez un accès suffisant pour entretenir et opérer l’appareil. • Assurez-vous d’une quantité...
  • Page 85 information générale information à propos de la plaque d’homologation Certified to Canadian and American National Standards: CSA 2.22-XXXX / ANSI Z21.50-XXXX for Vented Decorative Gas Appliances Certifié selon les normes Nationales Canadiennes et Américaines: CSA 2.22-XXXX / ANSI Z21.50-XXXX pour les Appareils à gaz décoratif à évacuation Direct vent, vented gas fireplaces.
  • Page 86 information générale dimensions W415-2881 / C / 03.07.22...
  • Page 87 2.0 exigences d'évacuation exigences d'évacuation AVERTISSEMENT • Risque d’incendie. Conservez les dégagements nécessaires au conduit d’évent et à l’appareil. • Les courses horizontales et verticales du système doivent être supportées à tous les 3 pi (0,9m). Utilisez l’ensemble de support mural Wolf Steel W010-0067 ou des attaches incombustibles équivalents afi n de maintenir le dégagement aux matériaux combustibles pour les courses verticales et horizontales.
  • Page 88 This template must be used in conjunction with templates 7.1.1 or 7.1.2, depending on termination shape (i.e. round, or round and square). See appropriate templates folder. exigences d'évacuation Pour une performance optimale de l’appareil et une apparence optimale des fl ammes, gardez la longueur des évents et le nombre de coudes au minimum.
  • Page 89 exigences d'évacuation 16" (40,6cm) minimum 40 pi (12m) maximum 3 pi (1m) minimum 20" (50,8cm) 24" 24" (61cm) (61cm) plus la pente * ÉVACUATION SUR L'ARRIÈRE * Voir la section « évacuation » W415-2881 / C / 03.07.22...
  • Page 90 exigences d'évacuation installations particulières d'évents 2.2.1 ensemble périscopique Utilisez l’ensemble périscopique afi n de positionner la terminaison au-dessus du niveau du sol. L’ensemble périscopique doit être installé de façon à ce que la fente d’air du bas soit située à un minimum de 12 pouces (305mm) au-dessus du niveau du sol.
  • Page 91 exigences d'évacuation emplacements et dégagements minimaux de la terminaison Applications pour balcon couvert ††* = 3 feet ≤ 15 feet = 2 x ACTUAL (0.9m) (4.6m) note: INSTALLATIONS Les terminaux du mur sont à des fi ns d’illustration seulement. La taille et les formes peuvent varier. Mesures des terminaux prises à...
  • Page 92 exigences d'évacuation charte d'application des évacuations ÉVACUATION SUR LE DESSUS Terminaison horizontale Terminaison verticale La course verticale La course verticale est La course verticale La course verticale est est plus petite que la plus grande ou égale à est plus petite que la plus grande ou égale à...
  • Page 93 exigences d'évacuation valeurs du coude en longueurs d'évent PIEDS POUCES MILLIMÈTRES 1° 0,03 12,7 15° 0,45 152,4 30° 11,0 279,4 45° 1,35 16,0 406,4 90°* 32,0 812,8 * La première déviation de 90° a une valeur zéro et est illustrée dans la formule comme - 90° 15.1A évacuation sur le dessus terminaison horizontale ) <...
  • Page 94 exigences d'évacuation ) > (V Configuration d'évacuation simple Consultez le graphique pour déterminer la course verticale nécessaire V (un coude de 90° seulement) par rapport à la course horizontale requise H 150 (381) 147 (373) COURSE VERTICALE 100 (254) REQUISE EN POUCES (CENTIMÈTRES)V 57 (145)
  • Page 95 exigences d'évacuation évacuation sur l'arriére terminaison horizontale ) < (V Configuration d'évacuation simple Consultez le graphique pour déterminer la course verticale nécessaire (deux coudes de 90° seulement) par rapport à la course horizontale requise H 40 (12,2) 38,3 (11,7) COURSE 30 (9,1) VERTICALE REQUISE...
  • Page 96 exigences d'évacuation ) > (V Configuration d'évacuation simple Consultez le graphique pour déterminer la course verticale (deux coudes de 90° seulement) nécessaire V par rapport à la course horizontale requise H 12,5 (3,8) 12,25 (3,7) COURSE VERTICALE 8,3 (2,54) REQUISE EN PIEDS (MÈTRES) V (1,68)
  • Page 97 exigences d'évacuation évacuation sur l'arriére et au dessus terminaison verticale ) < (V Consultez le graphique pour déterminer la course verticale Configurations d'évacuation simples. nécessaire V par rapport à la course horizontale requise H 40 (12,2) 30 (9,1) COURSE VERTICALE 20 (6,1) REQUISE EN PIEDS...
  • Page 98 exigences d'évacuation ) > (V Configurations d'évacuation simples. Consultez le graphique pour déterminer la course verticale nécessaire V par rapport à la course horizontale requise H 20 (6,1) 19 (5,8) COURSE VERTICALE REQUISE EN 10 (3,1) PIEDS (MÈTRES) V 3 (0,9) (1,5) (3,1) (4,6)
  • Page 99 exigences d'évacuation 2.10 évacuation à l'arrière AVERTISSEMENT • Il est essentiel que le couvercle d'évacuation soit installé. si non, l'appareil ne fonctionnera pas correcte- ment et pourrait causer des blessures ou des dommages matériels. Enlevez l'écran de protection et vitre de la porte (voir la section «...
  • Page 100 exigences d'évacuation 2.11 déflecteur du ventilation arrière (pour l'application de ventilation arrière) Retirez l'assemblage de l'écran de protection et la porte de l'appareil (voir la section « installation et enlevement de l'écran de protection et la porte »). Desserrez les deux vis servant à fixer la plaque d'évacuation, installez le déflecteur en glissant les ouvertures en forme de fentes derrière les têtes de vis, puis resserrez les vis (Fig.
  • Page 101 exigences d'évacuation 2.12 évacuation sur le dessus AVERTISSEMENT • Il est essentiel que le couvercle d'évacuation soit installé, si non, l'appareil ne fonctionnera pas correcte- ment et pourrait causer des blessures ou des dommages matériels. Enlevez l'écran de protection et vitre de la porte (voir la section « installation et enlevement de l'écran de protection et la porte »).
  • Page 102 encadrement approximatif 3.0 encadrement approximatif note: Lorsque vous installez les accessoires de fi nition optionelles, les dimensions de l’ossature et les matériaux de fi nition peuvent différer de ce qui est décrit dans ces instructions ci-dessous, voir les instructions fournies dans le trousse de l’accessoire pour les spécifi cations détaillées.
  • Page 103 encadrement approximatif dégagements minimaux de l'ossature SECTIONS D’ÉVENTS HORIZONTALES: Un dégagement minimal aux matériaux combustibles de 1" (25mm) au-dessous et sur les côtés de l’évent et de 3" (76,2mm) au-dessus doit être maintenu sur toutes les courses horizontales. note: Les dégagements minimaux entre le haut de l’évent et les matériaux combustibles peut être réduite de 3"...
  • Page 104 encadrement approximatif dégagements minimaux de l'enceinte ÉVACUATION SUR LE DESSUS PLAFOND ENCEINTE ENCEINTE AVEC ÉVACUATION SUR LE DESSUS L'enceinte de l'appareil doit avoir une hauteur minimale de 50 1/2" (128,3cm). Afin de respecter les contraintes de température, l’espace à l’intérieur de l’enceinte, autour de l'appareil et au-dessus, doit demeurer sans obstruction. note: L'écran de protection est télescopique et doivent être ajusté...
  • Page 105 encadrement approximatif ÉVACUATION À L'ARRIÈRE Pour la ventilation arrière ne dépassement pas 10" (254mm) de section horizontale de ventilation. Plafond Enceinte ENCEINTE AVEC ÉVACUATION À L'ARRIÈRE L'enceinte de l'appareil doit avoir une hauteur minimale de 41" (104,1cm). Afin de respecter les contraintes de température, l’espace à...
  • Page 106 encadrement approximatif DÉGAGEMENTS MAXIMAUX D'ÉVACUATION À L'ARRIÈRE (EXEMPLE 1: NICHE / BUMPOUT / ALCÔVE INTÉRIEUR) Plafond ENCEINTE AVEC ÉVACUATION À L'ARRIÈRE L'enceinte de l'appareil doit avoir une hauteur minimale de 41" (104,1cm). Afin de respecter les contraintes de température, l’espace à l’intérieur de l’enceinte, autour de l'appareil et au-dessus, doit demeurer sans obstruction.
  • Page 107 encadrement approximatif DÉGAGEMENTS MAXIMAUX D'ÉVACUATION À L'ARRIÈRE (EXEMPLE 2: ALCÔVE / NICHE EXTÉRIEUR) ENCEINTE AVEC ÉVACUATION À L'ARRIÈRE L'enceinte de l'appareil doit avoir une hauteur minimale de 41" (104,1cm). Afin de respecter les contraintes de température, l’espace à l’intérieur de l’enceinte, autour de l'appareil et au-dessus, doit demeurer sans obstruction.
  • Page 108 encadrement approximatif note: Pour les matériaux de finition plus lourds comme du marbre, nous vous recommandons d’ajouter un support additionnel à l’ossature. Assurez-vous que le support de plancher est adéquat pour l’appareil et le matériau de fintion. Avant d’encadrer votre appareil, déterminez les exigences de ventilation avant de décider de l’emplacement finale de l’appareil.
  • Page 109 installation d'évacuation 4.0 installation d'évacuation AVERTISSEMENT • Avant d’effectuer les branchements pour l’alimentation en gaz et électronique, assurez-vous de retirer toute composante non fi xée à l’intérieur de la chambre de combustion. • Si votre appareil comprend un système de télécommande, assurez-vous que le récepteur est à la position «...
  • Page 110 installation d'évacuation installation horizontale AVERTISSEMENT • L’espaceur coupe-feu doit être installé avec l’écran protecteur orienté vers le haut. • La terminaison ne doit pas être enchâssée dans le mur ou le revêtement extérieur plus que l’épaisseur de la bride de la plaque de montage. •...
  • Page 111 installation d'évacuation installation verticale Cette confi guration s’applique lorsque l’évacuation se fait à travers un toit. Des ensembles d’installation pour les différentes pentes de toit sont disponibles chez votre détaillant autorisé. Voir la section « accessoires » dans le manuel du propriétairepour commander l’ensemble spécifi que dont vous avez besoin.
  • Page 112 installation d'évacuation utilisation de composants d’évacuation flexibles ou rigides AVERTISSEMENT • Ne laissez pas la gaine fl exible se tasser contre les courses horizontales ou verticales et les coudes. Gardez-la tendue. • Des espaceurs sont fi xés à la gaine fl exible à intervalles prédéterminés afi n de garder un espace vide avec le conduit extérieur.
  • Page 113 installation d'évacuation 4.3.1 installation de la terminaison verticale AVERTISSEMENT • Conservez un espace minimale de 2 po (51mm) entre la base de la prise d’air et le collet de solin. Matériel de fi xation fourni avec les ensembles de terminal pour toit et raccord appropriées. Fixez le support de toit au toit à...
  • Page 114 installation d'évacuation 4.3.3 installation de la terminaison horizontale Mettez l’appareil en place. Mesurez la longueur #10x2" d’évent requise entre la terminaison et l’appareil en tenant compte de la longueur additionnelle CALFEUTRAGE nécessaire pour la surface du mur fi ni et tout chevauchement de 2”...
  • Page 115 installation d'évacuation 4.3.4 installation de la terminaison verticale AVERTISSEMENT • Conserves un espace minimal de 2” (51mm) entre la base de la prise d’air et le collet de solin. note: Avant de fi xer les coudes aux collets à l’arriére de l’appareil, enlevez 1 1/2” (38.1mm) au collet de 4” (101.6mm) Matériel de fi xation fourni avec les ensembles de terminaison pour toit et raccord appropriée.
  • Page 116 installation d'évacuation terminaison verticale à travers une cheminée existante AVERTISSEMENT • Risque d’incendie • Les confi gurations d’évacuation coaxiales à colinéaires ne doivent être utilisées que dans une cheminée ou une enceinte de nature incombustible. Une installation dans une enceinte combustible peut causer un incendie. Cet appareil est conçu pour être raccordé...
  • Page 117 installation d'évacuation 4.4.1 renstreignant des évents verticaux AVERTISSEMENT • Mettez hors tension de gaz et de l'alimentation électrique avant d'intervenir sur l'appareil. • L'appareil peut être chaud, pas de service jusqu'à ce que l'appareil est refroidi. • Pour l'utilisation sure et correcte de l'appareil, suivez les instructions d'évacuation exactement. •...
  • Page 118 5.0 information électrique information électrique schéma de câblage électronique AVERTISSEMENT • Ne raccordez pas l’interrupteur mural ou la soupape de gaz à l’alimentation électrique (110 volts). (où applicable) INTERRUPTEUR VERT ORANGE MARCHE/ARRÊT TRANSFORMATEUR IPI / CPI* ON / OFF BOÎTIER DÉBRANCHEZ CES DE PILES RACCORDS DE L’INTERRUP-...
  • Page 119 information électrique installation du sauvegarde de pile AVERTISSEMENT • Assurez-vous que le gaz et l'alimentation électrique de l'appareil sont éteints. • L'appareil peut être chaud. Ne pas entretenir avant que l'appareil ne soit refroidi. note: En cas d'une panne de courant, votre appareil peut fonctionner utilisant le sauvegarde de pile fourni. Enlevez l’écran de protection en le levant vers le haut hors des quatre vis d’épaulement.
  • Page 120 branchement de gaz 6.0 branchement du gaz AVERTISSEMENT • Risque d’incendie, d’explosion, ou d’asphyxie. Assurez-vous qu’il n’y ait aucune source d’allumage comme des étincelles ou une fl amme nue. • Soutenez le contrôle du gaz lorsque vous attachez le tuyau pour éviter de plier la conduite de gaz. •...
  • Page 121 opération (électronique) 7.0 opération (électronique) AVERTISSEMENT • Si ces instructions ne sont pas suivies à la lettre, un incendie ou une explosion pourraient s’ensuivre, causant des dommages matériels, des blessures corporelles ou des pertes de vie. • Si applicable, allumez toujours la veilleuse, que ce soit pour la première fois ou lorsque l’approvisionnement en gaz est épuisé, avec la porte vitrée ouverte ou retirée.
  • Page 122 B. Tournez l’interrupteur murale de l’appareil à la position « OFF ». C. Coupez l’alimentation électrique à l’appareil si un travail d’entretien doit être faites. D. Tournez le soupape fermeture manuelle vers la gauche « OFF ». Ne forcez pas. opération (électronique) veilleuse sur demande ADD TITLE: VEILLEUSE SUR DEMANDE...
  • Page 123 opération (électronique) 8.0 opération (millivolt) AVERTISSEMENT • Coupez l’alimentation électrique à l’appareil et laissez-le refroidir avant d’effectuer un entretien. Seulement un • Si ces instructions ne sont pas suivies à la lettre, un incendie ou une explosion pourraient s’ensuivre, causant technicien de service qualifi é...
  • Page 124 9.0 encadrement fini encadrement fini 16" 40.6cm dimensions minimaux de l'ossature FRENCH 35" 88,9cm 16" 40,6cm W415-2881 / C / 03.07.22...
  • Page 125 finitions 10.0 finitions AVERTISSEMENT • Risque d'incendie! • N'obstruez jamais l'ouverture sur le devant de l'appareil. • Ne frappez pas, ne claquez pas et n'égratignez pas la porte vitrée. Ne faites pas fonctionner l'appareil lorsque la porte vitrée est enlevée, fissurée, brisée ou égratignée. •...
  • Page 126 finitions 10.2 installation de l'hotte avant note: Cette hotte doit être installé si elle n’a pas déjà été installée en usine. La porte et l'écran de protection doivent être enlèvés. Retirez les vis de fixation de la partie supérieure de l'appareil, comme illustré. Installez l'avant hotte, assurer qu'elle est inclinée vers le bas lorsqu'il est installé.
  • Page 127 finitions 10.3 matériau de finition incombustible AVERTISSEMENT Les matériaux de finition incombustibles ne doivent pas dépasser de plus 4” (101,6mm) la façade de la porte (sur toutes côtés). Si des projections plus grandes sont requises, augmentez les dégagements des côtés et du dessus de 2"...
  • Page 128 finitions 10.4 dégagements minimaux de la tablette AVERTISSEMENT • Rique d’incendie. Conservez tous les dégagements aux matériaux combustibles spécifi és. Incapacité de se conformer à ces instructions peut causer un incendie ou une surchauffe. Assurez-vous que tous les dégagements (arrière, côtés, dessus, évents, tablette, façade, etc.) sont respectés à la lettre. •...
  • Page 129 finitions 10.5 installation encadrée AVERTISSEMENT • Installation d’une télévision ou d’autres appareils électroniques au-dessus de l’appareil peut provoquer une décoloration, la fonte, détérioration ou des autres dommages aux composants électroniques. Utiliser les autorisations que les lignes directrices et référer aux instructions qui se trouvent dans le manuel d’installation du fabricant de votre électroniques.
  • Page 130 Les bûches sont fragiles et devraient être manipulées avec soin. If applicable, insert the following statement: Les bûches PHAZER et les braises incandescentes, exclusives aux appareils Timberwolf, créent un effet If applicable, insert the following statement: “Les bûches PHAZER [et les braises incandescentes], exclusives aux Napoléon/Continental, créent un effet “Les bûches PHAZER...
  • Page 131 à Média Plateau à à Média Plateau à Tige Tige Média Média (Bûche n° 5) (Bûche n° 5) finitions Plateau Bord de Plateau Bord de à Média Plateau à à Média Plateau à Trous au des- Trous au des- Trous au des- sous de bûche sous de bûche Média...
  • Page 132 NOTE: ENSURE NOMENCLATURE IS NOTE: ENSURE NOMENCLATURE IS CONSISTENT THROUGHOUT. CONSISTENT THROUGHOUT. finitions IF SPACE IS LEFT OVER, USE THIS BOX TO IF SPACE IS LEFT OVER, USE THIS BOX TO SHOW CORRECT FINAL LOG PLACEMENT SHOW CORRECT FINAL LOG WITH LINE DRAWINGS.
  • Page 133 finitions 10.7 braises incandescentes AVERTISSEMENT • Obstruez pas ni fermer les orifi ces du brûleur. Le blocage des orifi ces du brûleur peut créer une fl amme irrégulière, des dépôts de carbone et un retard d’allumage. Déchirez les braises incandescentes en morceaux et placez une couche lâche sur le grillage du brûleur. Les braises devraient être déchirées très soigneusement en petits morceaux minces irréguliers, car seuls les côtés des fi bres exposées à...
  • Page 134 11.0 installation de la soufflerie optionnelle AVERTISSEMENT • Assurez-vous que l'appareil est complètement refroidi avant de commencer l'installation. • Afin d'éviter les risques de suffocation, gardez le sac d'emballage loin des bébés et des jeunes enfants. Ne le laissez pas traîner dans les berceaux, les lits, les pousettes, ou les parcs de jeu. Ce sac n'est pas un jouet. Nouez-le avant de le jeter.
  • Page 135 3/8” - 1/2” 3/8” - 1/2” thermocouple (9.5mm - 12.7mm) (9.5mm - 12.7mm) Flame must envelop La flamme doit envelopper 12.0 réglages upper la thermocouple de 3/8" à 3/8" to 1/2" 1/2" SIT ELECTRONIC IGNITION (12.7mm - 9.5mm) of (9.5mm - 12.7mm) thermocouple 12.1 réglage de la veilleuse...
  • Page 136 ODS - MILLIVOLT 12.2 réglage du venturi L’ouverture du volet d’air a été préréglée en usine selon le tableau ci-dessous: Indépendamment de l’orientation du venturi, plus le volet est fermé, plus la VENTURI flamme est jaune et aura tendance à causer des dépôts de carbone. Plus le volet est ouvert, plus la flamme est bleue et plus elle a tendance à...
  • Page 137 entretien 13.0 entretien AVERTISSEMENT • Coupez l’alimentation en gaz et l’alimentation électrique avant de procéder à l’entretien de l’appareil. • L’appareil peut être chaud. Attendez qu’il soit refroidi avant d’en faire l’entretien. • N’utilisez pas de produits abrasifs. • Ne peinture pas l’assemblage de la veilleuse. Cet appareil et son système d’évacuation devraient être inspectés avant la première utilisation et au moins une fois l’an par un technicien de service qualifi é.
  • Page 138 entretien 13.1 entretien annuel AVERTISSEMENT • Le caisson devient trés chaud lors du fonctionnement. Laissez l’appareil se refroidir complétement ou portez des gants antichaleur avant d’effectuer l’entretien. • Ne jamais aspirer des braises qui sont chaudes. • Ne peinturez pas l’assemblage de la veilleuse. •...
  • Page 139 entretien 13.2 remplacement de la vitre de porte AVERTISSEMENT • N’utilisez pas de matériaux de substitution. • La vitre peut étre chaude, ne touchez pas la vitre jusqu’à ce qu’elle ait refroidi. • Usez de prudence lorsque vous enlevez et jetez des débris de verrou des composants endommagés. Assurez-vous d’aspirer tous les débris deverre à...
  • Page 140 rechanges 14.0 pièces de rechange AVERTISSEMENT • Omettre de positionner les pièces conformément à ce manuel ou d’utiliser uniquement des pièces spécifi quement approuvées pour cet appareil peut causer des dommages matériels ou des blessures corporelles. Contactez votre détaillant pour les questions concernant les prix et la disponibilité des pièces de remplace- ment.
  • Page 141 pièces de rechange W415-2881 / C / 03.07.22...
  • Page 142 pièces de rechange W415-2881 / C / 03.07.22...
  • Page 143 pièces de rechange W415-2881 / C / 03.07.22...
  • Page 144 15.0 accessoires W415-2881 / C / 03.07.22...
  • Page 145 16.0 guide de dépannage (électronique) guide de dépannage AVERTISSEMENT • Allumez toujours la veilleuse, que ce soit pour la première fois ou lorsque l’approvisionnement en gaz est épuisé, avec la porte vitrée ouverte ou retirée. • Coupez l’alimentation en gaz et l’alimentation électrique avant de procéder à l’entretien de l’appareil. •...
  • Page 146 guide de dépannage (électronique) symptôme problème solution La veilleuse ne s’allume Câblage: pénurie, connexion Vérifi ez qu’il n’y a pas de connexions desserrées du thermocouple ni sonde de fl amme. pas. Il y a du bruit mais desserrée (rectifi cation de la Vérifi ez l’interrupteur de bloc n’est pas endommagée ou trop serré.
  • Page 147 Les broches de connecteur de Redresser les fi ls. endommagée fi ls sont courbeés. Câblage de la soupape est Remplacez la soupape. guide de dépannage (électronique) symptôme problème solution endommagée Moteur tourne, les Les piles du récepteur sont Remplacez les piles. symptôme problème solution...
  • Page 148 guide de dépannage (électronique) 17.0 guide de dépannage (millivolt) AVERTISSEMENT • Allumez toujours la veilleuse, que ce soit pour la première fois ou lorsque l’approvisionnement en gaz est épuisé, avec la porte vitrée ouverte ou retirée. • Coupez l’alimentation en gaz et l’alimentation électrique avant de procéder à l’entretien de l’appareil. •...
  • Page 149 3/8” - 1/2” guide de dépannage (millivolt) (9.5mm - 12.7mm) La flamme doit envelopper la thermocouple de 3/8" à symptôme problème solutions 1/2" (9.5mm - 12.7mm) La veilleuse ne Aucune étincelle au brûleur de la Vérifi ez si la veilleuse peut être allumée avec une allumette. s’allume pas.
  • Page 150 à aucun dommage accidentel, consécutif ou indirect. Cette garantie défi nit l’obligation et la responsabilité de Timberwolf® en ce qui concerne le foyer au gaz Timberwolf®. Toute autre garantie énoncée ou implicite en ce qui concerne ce produit, ses composants ou accessoires est exclue.
  • Page 151 notes 29.1 W415-2881 / C / 03.07.22...
  • Page 152 Produits et distribués par: 24 Napoleon Road, Barrie, Ontario, Canada L4M 0G8 Tél: 1-866-820-8686 timberwolffireplaces.com...

Ce manuel est également adapté pour:

Tb36ntrTb36ntreTb36ptrTb36ptre