Télécharger Imprimer la page

Best HBC143ESS Instructions D'installation, D'utilisation Et D'entretien page 11

Publicité

Les langues disponibles

Les langues disponibles

PM6 Blower Connection
1. Swivel the connectors plate to unhide a connector.
2. Plug the blower power cord in the connector as
illustrated above.
EXTERNAL BLOWER PROGRAMMING PROCEDURE
This range hood is designed to work with several different blower models. Before using the hood, the control must first
be programmed for your blower model in order to achieve proper operating speed:
1. Find the SETUP number that corresponds to the blower model that is installed with your range hood.
SETUP 1
ILB6
NOTE: If no button is touched for more than 3 seconds while the hood is in programming mode, the hood will exit
the programming mode without saving the changes.
2. There must be power to the hood but the blower and lights must be turned off.
3. To change the setup, press and hold BLOWER and LIGHT buttons simultaneously for 6 seconds and release, then:
To set the range hood at SETUP 1, press BLOWER button until button 1 alone lights up.
To set the range hood at SETUP 2, press BLOWER button until both buttons 1 and 2 light up.
4. Press DELAY OFF button to save and leave programming mode.
5. If needed, verify which setting the hood is currently in. To do so:
Press and hold BLOWER and LIGHT buttons simultaneously for 6 seconds and release. Different
combinations of SPEED buttons (1 to 4) will turn ON for 3 seconds, depending on the setting.
NOTE:
11
Connectors plate
SETUP 2
EB15
ILB9
If set at SETUP 3, SPEED buttons 1, 2, 3 and 4 will light up.
If set at SETUP 2, SPEED buttons 1 and 2 will light up.
If set at SETUP 1, SPEED button 1 will light up.
To reset to default, press and hold BLOWER and LIGHT buttons simultaneously for 6 seconds and release.
Different combinations of SPEED buttons (1 to 4) will turn ON for 3 seconds. Press and hold LIGHT button
for 3 seconds then SPEED buttons will flash 3 times. Setting is back to original status.
PM12 Blowers Connection
FIG. 5
1. Remove the connectors plate.
2. Plug each blower power cord in a connector as
illustrated above.
Service parts:
(1) 600
BLOWER
/
ADAPTER
DAMPER
SETUP 3 (by default)
EB9
ILB11
: S97021509
CFM
8"
: SV08543
ROUND
FIG. 6

Publicité

loading

Ce manuel est également adapté pour:

Hbc1 serieHbc163essHbc143ewh