BLOWER INSTALLATION
This hood is compatible with the following blowers. Select a blower model among these: internal blower - PM6 or PM12,
exterior blower - EB9 or EB15, in-line blower - ILB6, ILB9 or ILB11. For exterior and in-line blowers, refer to the installation
instructions provided with the blower for more details.
NOTE: Rough-in plate included with exterior blower kit is not needed for ceiling hood application.
PM6 OR PM12
PM6 Blower Plate Installation
1. Attach blower to mounting plate with (6) 10-24 Hex
Nuts (included).
2. Attach ground wire from blower to ground stud with
(1) 10-24 Hex Nut (included).
NOTES: There are four (4) possible outlet positions for PM6 and PM12: top, front, back and side. Remove selected
knock-out from the housing prior to install blower in the hood. The blower can be installed before or after hood
installation in the ceiling. However, it is easier to install the hood in the ceiling without internal blower installed.
The damper can be installed on the housing prior to install the hood in the ceiling with Side and Top outlet
positions only. Otherwise, install the damper once the hood is mounted in the ceiling. Position the damper on the
exterior of the hood using 8-18 screws (included).
10" damper (included with the hood) when using PM12, 8" damper (included with PM6 blower kit) when
using PM6.
Top Discharge Blower Installation (PM6 shown in
FIG. 3 & 5). Follow same method for PM12.
10
1. Attach blower plate to hood with (4) 10-24 screws
(included) as illustrated above.
BLOWER INSTALLATION
G
S
ROUND
TUD
PM12 Blower Plate Installation
FIG. 1
1. Attach blowers to mounting plate with (12) 10-24 Hex
Nuts (included).
2. Attach ground wires from blowers to ground studs
with (2) 10-24 Hex Nut (included).
Front/Back Discharge Blower Installation (PM12 Front
shown in FIG. 4 & 6). Follow same method for Side
Discharge and when using PM6 blower.
FIG. 3
1. Attach blower plate to hood by inserting the hooks in the
slots and using (2) 10-24 screws (included) as illustrated
above.
G
S
ROUND
TUD
G
ROUND
Side Discharge
S
TUD
FIG. 2