ELECTRICAL CONNECTIONS TO THE TERMINALS AND THEIR FUNCTIONS
Accessory
Photocells in closing
ZERO.PH
Orbita 57
Key-switch
ZERO.K
ZERO.EK
Radio contact
Warning lamp output
24 V - 1 W
24 Vdc output
V IX 5 3
Output 24 Vdc
for DSA control
ELPRO 65
Electrical connections
All of the NC contacts on the
1 2
photocells in closing phase must be
connected in series to the terminals 1
and 2
NC
NC
NO and NC contacts to be connected
3 4 5 6
to the respective terminals of the key or
button-switches.
All the possible configurations are
attached to their respective command
NC
accessories
By
connecting
3
7
between the two terminals, each
impulse can perform:
- Only opening:
dip 2 = ON and dip 5 = OFF
- Reverse direction on each impulse
RADIO
dip 2 = OFF and dip 5 = OFF
CONTACT
- Step by step: open-stop-close-stop
dip 2 = OFF and dip 5 = ON
Output for a possible automation status
8
9
warning lamp:
Warning lamp on = gate open
Warning lamp off = gate closed
Flashing at 0,5 s (fast) = closing movement
Flashing at 1 s (normally) = opening
movement
24 Vdc OUTPUT for max load:
9
10
n° 2 pairs of photocells
n° 1 radio receiver
n° 1 led key-switch ZERO.K / ZERO.EK
All the instructions are attached to their
respective command accessories
24 Vdc output to power the photocell
13 1 14 4
trasmitters (connected in parallel) for the
DSA control: Autotest Safety Device = if
activated, before opening or closing
movements all the security devices are
checked for faults.
In case any malfunction is detected, the
operator is prevented from starting and the
LED on the Junior cover keeps flashing with
alternated blue and orange lights.
Dip-switches and LED indication of their functions
DIP-SWITCH 1
1
DIP-SWITCH 2 and 5
any
NO
contact
(MUST NOT ever be simultaneously ON):
2
5
DIP-SWITCH 10
10
28
ON: stops gate on opening and reverses it on
closing once obstacle is removed
OFF: no stop on opening, gate is reversed on
closing in case of an obstacle
L2 green on: no obstacle, it turns off in case of
obstacle
L4 red off: no contact OPEN, it lights up with
each opening impulse
L5 red off: no contact CLOSE, it lights up with
each closing impulse
L6 green on: STOP contact closed, it turns off at
each stop contact
ON: does not reverse and does not stop in
opening
OFF: in opening always stops and reverses
ON: step by step with intermediate stop
OFF: reverses direction on every impulse
L7 red off: no RADIO contact, it lights on at
every impulse to radio contact
ON: DSA control of the photocells.
The photocell projectors, outputs 13-14, must
be powered
OFF: No DSA control of the photocells