6
Program overview
Menu 3 Basic settings
Menu
Entry
Selection
item
30
Door setting of upper end position
Reversal of the direction (press for 5 s)
31
Door setting of lower end position
32
Door setting for 1/2 opening position
33
Fine correction of upper end position
50
Factory settings
50 - 0
0...80 mm lower
50 - 99 0...80 mm higher
34
Fine correction of lower end position
50
Factory settings
50 - 0
0...80 mm lower
50 - 99 0...80 mm higher
35
Selection of closing edge safety device
Measurement display (press 5 seconds)
0
Optical closing edge safety device OSE
(default setting)
1
Electrical safety edge 8K2
2
Pressure wave switch with testing
3
Electrical safety edge 8K2 with slack rope
switch
4
Wireless closing edge, RadioBand
36
Selection of photoelectric sensor
0
Without photoelectric sensor (default setting)
1
2-wire photoelectric sensor LS2
2
4-wire photoelectric sensor LS5 photoelectric
reflection sensor
3
Photoelectric sensor LS2, mounted in frame
4
Photoelectric sensor LS5 photoelectric
reflection sensor mounted in frame
5
2-wire photoelectric sensor LS2 with stop
function for opening
6
4-wire photoelectric sensor LS5 with stop
function for opening
37
Correction of pre-limit switch closing edge safety
25
Correction of pre-limit switch closing edge
safety (default setting)
25 - 0
0...50 mm lower
25 - 99 0...100 mm higher
- -
Exit menu
Menu 4 Further door settings
Menu
Entry
Selection
item
40
Selection of operating mode
0
Dead man OPEN / dead man CLOSE
1
Pulse OPEN / dead man CLOSE
2
Pulse OPEN / pulse CLOSE (default setting)
3
AR - automatic closing
4
AR - with reduction of the hold-open time
5
Open/close operation, red/green light with
A800 (option)
6
As in 5, however, with reduction for
photoelectric sensor
26 - EN
Menu 4 Further door settings
Menu
Entry
Selection
item
41
Response to closing edge safety device
0
Full reversing (default setting)
1
Partial reversing
42
Overtravel correction
0
Off
1
On (default setting)
43
Floor adjustment
0
Off (default setting)
1
Advanced end stop by closing edge
2
Floor adjustment activated for 200 cycles
3
Floor adjustment activated for 1000 cycles
4
Permanent floor adjustment
44
Hold-open time in seconds
0
0 s (default setting)
1 - 30
1 s - 30 s (in increments of 1 s)
31 - 60 35 s - 180 s (in increments of 5 s)
61 - 99 190 s - 22.5 min (in increments of 30 s)
45
Status relay X5
0
Door close signal (default setting)
1
Door open signal
2
2-minute garage light
3
5-minute garage light
4
On/off with hand-held transmitter
5
ELTACO wipe pulse
6
Control of electronic door lock EDL100
(optional)
46
Status relay X6
0
Door close signal
1
Door open signal (default setting)
2
Red light without advance warning time
3-12
Advance warning time before closing 1 s -
10 s
13-22
Advance warning time before opening and
closing 1 s - 10 s
47
Spring fracture detection
Spring balance indication (press for 5 s)
0
Off (default setting)
1-99
Entry of spring force
48
Opening force limitation
0
Off (default setting)
1-98
Entry of switch-off force
99
Carry out weight measurement run with test
weight
49
Motor duty cycle
0
Without limitation (default setting)
1
Geared motor 5.24 (25 min / 35 %)
2
Geared motor 5.24 WS (25 min / 30 %)
3
Geared motor 9.15, 9.20, 9.24 (25 min / 60 %)
4
Geared motor 9.24 WS (25 min / 20 %)
5
Geared motor 6.65 DU (10 min / 35 %)
6
Geared motor 14.15 (25 min / 60 %)
- -
Exit menu
T100 DES