3. Cut the required openings in the cabinetry to provide proper
ventilation to the Induction Warmer. Refer to the "Ventilation
Requirements" in this section for details.
4. If necessary, make structural modifications or add bracing
underneath the countertop to ensure the countertop will
support the weight of the unit and its contents.
NOTE: The countertop must be level to ensure proper operation
of the Induction Warmer.
5. Apply a bead of NSF-approved silicone sealant onto the
countertop material around the cutout opening.
NOTE: The silicone sealant must be rated for use at
temperatures up to 250°F (121°C)
6. Install the trim ring into the countertop opening.
7. Carefully lower the unit into the trim ring, making sure the
power cord and control cable do not get pinched.
Cutaway view of trim ring.
Silicone
Back
of
Unit
Standard Trim Ring Installation
8. Apply a bead of NSF-approved silicone sealant in the gap
between the trim ring and the Induction Warmer.
a. Make sure the unit is centered in the trim ring.
b. Install masking tape on each side of the gap to define the
edge of the sealant.
c. Carefully apply sealant into the gap.
d. Quickly smooth the sealant surface.
e. Carefully remove the masking tape before the sealant
dries.
NOTE: The silicone sealant must be rated for use at
temperatures up to 250°F (121°C)
9. Install the control panel in the desired location. Refer to the
"Installing the Control Panel" procedure.
10. Plug the unit into a properly grounded electrical receptacle
of the correct voltage, size, and plug configuration. See the
SPECIFICATIONS section for details.
Form No. IWRMM-0119
Installing the Control Panel
Use the following procedure to install the control panel.
Remote mounted control panel must be mounted on a
vertical wall and installed in vertical position. Mounting
control panel in horizontal position may result in collection
of liquids and lead to an electric shock.
1. Carefully measure and cut the opening in the cabinet wall
2. Drill the appropriate holes around the cutout for the control
Trim
Ring
1-13/16"
(46 mm)
Front
of
Unit
Countertop
3. Apply a 1/4" (6 mm) bead of NSF-approved silicone sealant
4. Position the control panel into the cutout opening through
5. Fasten the control panel to the vertical surface using four
6. Connect the control cable on the control panel to the control
9
WARNING
for the control panel.
panel mounting screws (not supplied).
Silicone Sealant
Cabinet Wall
(129 mm)
(111 mm)
3/16"
(4 mm)
Control Panel Cutout and Screw Hole Dimensions
where the trim on the control panel will contact the cabinet
surface. Refer to the "Control Panel Cutout and Screw Hole
Dimensions" illustration for silicone placement.
the front of the cabinet. Make sure to embed the trim on the
control panel into the silicone.
mounting screws (not supplied).
cable port on the bottom of the induction range.
Silicone
Sealant
Mounting Screw
Installing the Control Panel
INSTALLATION
1-1/2"
(38 mm)
5-1/8"
4-3/8"
3/8"
(9 mm)
C a b in e t W
a ll
Control Cable