Hatco IWRM Série Manuel D'installation Et D'utilisation page 8

Réchaud à induction
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

INSTALLATION
Flush Mount Installation
Flush mount installation requires a prepared, solid material
countertop and provides a seamless transition between the
countertop and the induction range. A special, "stepped" cutout
is required for flush mount installation.
NOTE: A Flush Mount Kit is available as an accessory that
enables flush mount installation in a straight, non-
stepped countertop cutout. Refer to OPTIONS AND
ACCESSORIES for details.
1. Carefully measure and cut the step-style opening in the
countertop. The thickness of the solid material countertop
material should be a minimum of 3/4" (19 mm).
a. Refer to the Flush Mount Countertop Cutouts illustration
below for the dimensions of each cutout.
• Two cutouts are required;
a partial depth outer
cutout, and an inner
cutout—the
material
between the cutouts is
removed. This creates a
step for the flange of the
Induction Warmer to sit
on below the level of the
countertop.
b. Create the outer, partial depth cutout.
• Depth = 3/8" (9.5 mm)
c. Create the inner cutout. Then, remove the material in
between the cutouts to create the step.
13-1/8"
(333 mm)
Outer Cutout
Inner Cutout
Flush Mount Countertop Cutouts
2. Cut and drill the appropriate holes in the vertical surface
where the control enclosure will be installed. Refer to
the "Installing the Control Panel" procedure for cutout
dimensions.
3. Cut the required openings in the cabinetry to provide proper
ventilation to the induction range. Refer to the "Ventilation
Requirements" listed previously in this section.
4. If necessary, make structural modifications or add bracing
underneath the countertop to ensure the countertop will
support the weight of the unit and its contents.
NOTE: The countertop must be level to ensure proper operation
of the Induction Warmer.
Step
Outer Cutout
3/8" (9.5 mm)
Countertop
Inner Cutout
11-13/16"
(300 mm)
12-1/4"
(311 mm)
13-1/8"
(333 mm)
5. Carefully lower the unit into the opening, making sure the
power cord does not get pinched.
Silicone
Back
of
Unit
Power Cord
Standard Flush Mount Installation
6. Apply a bead of National Sanitation Foundation (NSF)-
approved silicone sealant in the gap between the
countertop and the Induction Warmer. To apply a clean,
consistent sealant bead:
a. Make sure the unit is centered in the countertop cutout.
b. Install masking tape on each side of the gap to define the
edge of the sealant.
c. Carefully apply sealant into the gap.
d. Quickly smooth the sealant surface.
e. Carefully remove the masking tape before the sealant
dries.
NOTE: The silicone sealant must be rated for use at
temperatures up to 250°F (121°C)
7. Install the control panel in the desired location. Refer to the
"Installing the Control Panel" procedure.
8. Plug the unit into a properly grounded electrical receptacle
of the correct voltage, size, and plug configuration. See the
SPECIFICATIONS section for details.
Trim Ring Installation
Trim ring installation requires the purchase of the accessory
trim ring and can be performed in a solid material or stainless
steel countertop.
TRIM-IWRM1 = Model IWRM-B1-1313-06
Use the following procedure for trim ring installation.
1. Carefully measure and cut the opening in the countertop.
13-1/2"
(343 mm)
Trim Ring Installation Countertop Cutout
2. Cut and drill the appropriate holes in the vertical surface
where the control enclosure will be installed. Refer
to the "Installing the Control Panel" procedure in the
INSTALLATION section for details.
8
Front
of
Unit
Countertop
Control Cable Port
13-1/2"
(343 mm)
Form No. IWRMM-0119

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Iwrm-c1-1317-06Iwrm-cd1-03Iwrm-b1-1313-06