INSTALLATION
OUTSIDE AIR SUPPLY
INSTALLING IN A MOBILE HOME)
Depending
on
your
construction, outside air may be necessary for
optimal performance. Your stove is approved to be
installed with an outside air intake (69FAK) which
is necessary for a mobile home. You can purchase
the 69FAK through your heater dealer. Installation
instructions are supplied with the air intake kit.
ATTENTION:
DO NOT VENT UNDER ANY PORCH, DECK,
AWNING, OR IN ANY SEMI ENCLOSED OR
ROOFED AREA. DOING SO MAY RESULT IN
UNPREDICTABLE AIRFLOW AT THE VENT
CAP UNDER CERTAIN CONDITIONS AND CAN
AFFECT THE PERFORMANCE OF YOUR STOVE,
AS WELL AS, OTHER UNFORESEEABLE ISSUES.
SECURING APPLIANCE TO THE FLOOR
Use the designated holes to secure the unit to the
floor.
Exhaust
Pipe
WARNING! DO NOT INSTALL IN SLEEPING ROOM.
CAUTION! THE STRUCTURAL INTEGRITY OF THE
MOBILE HOME FLOOR, WALL, AND CEILING/ROOF
MUST BE MAINTAINED.
WHEN INSTALLED IN A MOBILE HOME, THE
STOVE MUST BE GROUNDED DIRECTLY TO THE
STEEL CHASSIS AND BOLTED TO THE FLOOR.
In addition to the previously detailed installation
requirements, mobile home installations must
meet the following requirements:
• This stove must be securely fastened to the floor of the
mobile home through the two holes in the rear of the
stove using 2, 1/4" lag bolts that are long enough to go
(OPTIONAL, UNLESS
location
and
home
Fresh Air
Intake
through both a hearth pad, if used, and the floor of the
home.
• The heater must be electrically grounded to the steel
chassis of the mobile home with 8 GA copper wire
using a serrated or star washer to penetrate paint or
protective coating to ensure grounding.
• Vent must be 3 or 4-inch "PL" Vent and must extend
a minimum or 36" (914 mm) above the roof line of the
mobile home and must be installed using a certified
ceiling fire stop and rain cap.
• When moving your mobile home, all exterior venting
must be removed while the mobile home is being
relocated. After relocation, all venting must be
reinstalled and securely fastened.
• Outside Air is mandatory for mobile home installation.
See Outside Air Supply section and your dealer for
purchasing.
• Check with your local building officials as other codes
may apply.
VENTING REQUIREMENTS
• INSTALL VENT AT CLEARANCES SPECIFIED BY
THE VENT MANUFACTURER.
• DO NOT CONNECT THE PELLET VENT TO A VENT
SERVING ANY OTHER APPLIANCE OR STOVE.
• DO NOT INSTALL A FLUE DAMPER IN THE
EXHAUST VENTING SYSTEM OF THIS UNIT.
The following installation guidelines must be
followed to ensure conformity with both the safety
listing of this stove and to local building codes. Do
not use makeshift methods or compromise in the
installation.
THIS UNIT IS EQUIPPED WITH A NEGATIVE
DRAFT SYSTEM THAT PULLS AIR THROUGH
THE BURN POT AND PUSHES THE EXHAUST
OUT OF THE DWELLING. IF THIS UNIT IS
CONNECTED TO A FLUE SYSTEM OTHER THAN
THE WAY EXPLAINED IN THIS MANUAL, IT
WILL NOT FUNCTION PROPERLY.
MAXIMUM VENTING DISTANCE
Installation MUST include at least 3-feet of vertical
pipe outside the home. This will create some natural
7
© 2022 United States Stove Company
WARNING:
IMPORTANT: