Publicité

Liens rapides

Owner's Instruction and Operation Manual
Model Number:
AP5613
Report Number: F21-735
Certified to ASTM E1509-12 (2017)
and Certified to ULC-S627-00-
REV1
Mobile Home Approved
* All Pictures In This Manual Are For Illustrative Purposes Only. Actual Product May Vary.
Save These Instructions In A Safe Place For Future Reference.
SAFETY NOTICE: If this heater is not properly installed, a house fire may result.
For your safety, follow the installation instructions. Never use make-shift
compromises during the installation of this heater. Contact local building or
fire officials about permits, restrictions and installation requirements in your
area. NEVER OPERATE THIS PRODUCT WHILE UNATTENDED.
CAUTION! Please read this entire manual before you install or use your new room
heater. Failure to follow instructions may result in property damage, bodily injury,
or even death. Improper Installation Will Void Your Warranty!
U.S. Environmental Protection Agency
Certified to comply with 2020 particulate
emissions standards.
THIS MANUAL IS SUBJECT TO CHANGE WITHOUT NOTICE.
© 2022 United States Stove Company, 227 Industrial Park Rd., South Pittsburg, TN 37380
R
CALIFORNIA PROPOSITION 65 WARNING:
This product can expose you to chemicals including carbon
monoxide, which is known to the State of California to cause
cancer, birth defects, and/or other reproductive harm. For
more information, go to www.P65warnings.ca.gov
853913B-2302L
Ph. 800-750-2723

Publicité

Table des Matières
loading

Sommaire des Matières pour Ashley AP5613

  • Page 1 Owner’s Instruction and Operation Manual Model Number: AP5613 Report Number: F21-735 Certified to ASTM E1509-12 (2017) and Certified to ULC-S627-00- REV1 Mobile Home Approved 853913B-2302L * All Pictures In This Manual Are For Illustrative Purposes Only. Actual Product May Vary.
  • Page 2 Your stove is Certified to ASTM E1509-12 (2017)and Certified to ULC S627- 00. This manual describes the installation and operation of the U.S. Stove, AP5613 wood heater. This heater meets the 2020 U.S. Environmental Protection Agency’s crib wood emission limits for wood heaters sold after May 15, 2020.
  • Page 3: Installation Checklist

    INSTALLATION CHECKLIST Your Wood Stove should be installed by a qualified installer only. An NFI qualified Installer can be found at www.nficertified.org/public/find-an-nfi-pro/ CUSTOMER SERVICE 1-800-750-2723 ext 5050 Text to 423-301-5624 Email to: Customerservice@usstove.com COMMISSIONING CHECKLIST This Checklist is to be completed in full by the qualified person who installs this unit. Keep this page for future reference.
  • Page 4 ASSEMBLY INSTRUCTIONS FOR CUSTOMER SERVICE CALL: 800-750-2723 EXT 5050 Pull the factory installed wires out of the top of 3. Connect the factory installed wiring harnesses the stove. There will be two wire harnesses, as to the control panel as shown. shown.
  • Page 5 INSTALLATION SAFETY NOTICE CAUTION: • IF THIS STOVE IS NOT PROPERLY INSTALLED, BURNING FUEL CREATES CARBON MONOXIDE A HOUSE FIRE MAY RESULT. TO REDUCE THE AND CAN BE HAZARDOUS TO YOUR HEALTH RISK OF FIRE, FOLLOW THE INSTALLATION IF NOT PROPERLY VENTED. INSTRUCTIONS.
  • Page 6: Floor Protection

    INSTALLATION FOR CUSTOMER SERVICE CALL: 800-750-2723 EXT 5050 CLEARANCES https://nficertified.org, Your pellet stove has been tested and listed https://www.wettinc.ca/ for installation in residential, mobile home in accordance with the clearances given below. For IMPROPER INSTALLATION safety reasons, please adhere to the installation The use of other components other than stated clearances and restrictions.
  • Page 7: Venting Requirements

    INSTALLATION OUTSIDE AIR SUPPLY rear of the stove using 2, 1/4” lag bolts that are (OPTIONAL, UNLESS INSTALLING IN A MOBILE HOME) long enough to go through both a hearth pad, if Depending your location home used, and the floor of the home. construction, outside air may be necessary for •...
  • Page 8: Pellet Vent Termination

    INSTALLATION MAXIMUM VENTING DISTANCE enable collection of fly ash and to permit periodic cleaning of the exhaust system. 90-degree elbows Installation MUST include at least 3-feet of vertical accumulate fly ash and soot thereby reducing pipe outside the home. This will create some natural exhaust flow and performance of the stove.
  • Page 9 INSTALLATION beside any door or window that opens. Your heater dealer should be able to provide you with a kit that will handle most of this installation, B. Minimum 1-foot (0.3m) clearance above any which will include a wall thimble that will allow door or window that opens.
  • Page 10 INSTALLATION WARNING: You may want to locate any utilities or obstacles inside the wall before attempting this install. Make sure to keep in mind your unit’s clearance requirements. Mark the area and then cut the wall for vent installation if needed. 2.
  • Page 11 OPERATION INSTRUCTIONS NEVER OPERATE THIS PRODUCT WHILE UNATTENDED PANEL CONTROLS range “1” to heat range “5”. C. °C / °F Button • The °C / °F button changes the two digit display from degrees Celsius to degrees Fahrenheit. D. MODE (M/T) BUTTON •...
  • Page 12 OPERATION INSTRUCTIONS located inside the hopper. Note: The factory default 9. Manure or animal remains; setting for this is full open. To decrease the flow of 10. Salt water driftwood or other previously salt pellets, move the fuel adjuster down. water saturated materials;...
  • Page 13: Building A Fire

    OPERATION INSTRUCTIONS but may seriously impair the stoves performance NOTE: During the first few fires, your stove will by generating considerable smoke. Do not burn emit an odor as the high-temperature paint cures wet pellets. The stove’s performance depends or becomes seasoned to the metal. Maintaining heavily on the quality of your pellet fuel.
  • Page 14: Opening Door

    OPERATION INSTRUCTIONS OPENING DOOR WARNING: • KEEP HOPPER LID CLOSED AT ALL TIMES CAUTION: EXCEPT WHEN REFILLING. • DO NOT OPERATE YOUR STOVE WITH • DO NOT OVERFILL HOPPER. THE VIEWING DOOR OPEN. THE AUGER WILL NOT FEED PELLETS UNDER THESE TAMPER WARNING CIRCUMSTANCES AND A SAFETY CONCERN This wood heater has a manufacturer-set minimum...
  • Page 15 OPERATION INSTRUCTIONS OPTIMAL OPERATION This pellet stove has been certified by the US EPA to meet strict 2020 guidelines. To Insure this unit produces the optimal minimal emissions, it is critical to follow the following guidelines.To achieve a “high burn” your stove should be set on setting 5 with the damper fully open.To achieve a “medium Clean-Out burn”...
  • Page 16 MAINTENANCE NEVER OPERATE THIS PRODUCT WHILE UNATTENDED at the chimney top. Cooler surfaces tend to build CAUTION: creosote deposits quicker, so it is important to • FAILURE TO CLEAN AND MAINTAIN THIS check the chimney from the top as well as from the UNIT AS INDICATED CAN RESULT IN POOR bottom.
  • Page 17: Painted Surfaces

    MAINTENANCE BLOWER MOTORS Let the fire burn out and allow the unit to cool to room temperature. Clean the air holes on the motors of both the exhaust and distribution blowers annually. Remove 2. Make sure the pellet stove is at room the exhaust blower from the exhaust duct and temperature before touching.
  • Page 18: Maintenance Schedule

    MAINTENANCE MAINTENANCE SCHEDULE Monthly or Daily Weekly Use the following as a guide under average use as needed conditions. Gaskets around door and door glass Burn Pot Stirred Empty should be inspected and repaired or replaced when necessary. Combustion Brushed Chamber Ashes Check...
  • Page 19: Troubleshooting Guide

    TROUBLESHOOTING GUIDE When your stove acts out of the ordinary, the first reaction is to call for help. This guide may save time and money by enabling you to solve simple problems yourself. Problems encountered are often the result of only five factors: 1) poor fuel;...
  • Page 20 TROUBLESHOOTING GUIDE Display is Flashing “E2” Possible Causes Possible Remedies: (Unplug stove first when possible) Unhook air hose from the air switch and blow through it. Airflow switch hose or stove attachment If air flows freely, the hose and tube are fine. If air will not pipes for hose are blocked.
  • Page 21 TROUBLESHOOTING GUIDE Display is Flashing “E3” Possible Causes Possible Remedies: (Unplug stove first when possible) The hopper is out of pellets Refill the hopper. The air dampener is too far open for a low If on the low setting, you may need to close the dampener feed setting all the way.
  • Page 22 TROUBLESHOOTING GUIDE Display is Flashing “E4” Possible Causes Possible Remedies: (Unplug stove first when possible) The air inlet, burnpot, interior combustion chambers, combustion blower, Follow all cleaning procedures in the maintenance section exhaust pipe are blocked with ash or foreign of the owner’s manual.
  • Page 23 TROUBLESHOOTING GUIDE Stove Feeds Pellets, But Will Not Ignite Possible Causes Possible Remedies: (Unplug stove first when possible) In some situations it may be necessary to have the damper completely closed for ignition to take place. After there is Air damper open too far for ignition. a flame, the damper can then be adjusted for the desired feed setting.
  • Page 24 TROUBLESHOOTING GUIDE Stove Will Not Feed Pellets, But Fuel Feed Light Comes On As Designed Possible Causes Possible Remedies: (Unplug stove first when possible) Wait for the stove to cool for about 30 - 45 minutes. Locate the High Limit thermodisc and press the reset button on the back of it.
  • Page 25 TROUBLESHOOTING GUIDE High Limit Switch Keeps Tripping Possible Causes Possible Remedies: (Unplug stove first when possible) The convection blower is overheating and Clean any dust off of the windings and fan blades. If oiling tripping the internal temperature shutoff. the blower does not help, the blower may be bad. If operating the heater on the highest heat setting, the The stove is being left on the highest setting room temperature could increase enough and lead to...
  • Page 26: Repair Parts

    Ceramic Ignitor 88118 Ignitor Flange Gasket IN ORDER TO MAINTAIN WARRANTY, COMPONENTS MUST BE REPLACED USING ASHLEY PARTS PURCHASED THROUGH YOUR DEALER OR DIRECTLY FROM ASHLEY. USE OF THIRD PARTY COMPONENTS WILL VOID THE WARRANTY. © 2022 United States Stove Company...
  • Page 27: Wiring Diagram

    WIRING DIAGRAM 7.5A 250V FUSE 1.25A 250V FUSE Ensure the wires are connected to the bottom two prongs of the hopper switch as shown. CORRECT WRONG © 2022 United States Stove Company...
  • Page 28 NOTES © 2022 United States Stove Company...
  • Page 29: Service Record

    SERVICE RECORD It is recommended that your heating system is serviced regularly and that the appropriate Service Interval Record is completed. SERVICE PROVIDER Before completing the appropriate Service Record below, please ensure you have carried out the service as described in the manufacturer’s instructions. Always use the manufacturer's specified spare part when replacement is necessary.

Table des Matières