SAFETY NOTICE: If this heater is not properly installed, a house fire may result. For
your safety, follow the installation instructions. Never use make-shift compromises
during the installation of this heater. Contact local building or fire officials about
permits, restrictions and installation requirements in your area. NEVER OPERATE
THIS PRODUCT WHILE UNATTENDED.
CAUTION! Please read this entire manual before you install or use your new room
heater. Failure to follow instructions may result in property damage, bodily injury, or
even death. Improper Installation Will Void Your Warranty!
U.S. Environmental Protection Agency
Certified to comply with 2020 particulate
emissions standards.
THIS MANUAL IS SUBJECT TO CHANGE WITHOUT NOTICE.
© 2022 United States Stove Company, 227 Industrial Park Rd., South Pittsburg, TN 37380
R
CALIFORNIA PROPOSITION 65 WARNING:
This product can expose you to chemicals including carbon
monoxide, which is known to the State of California to cause
cancer, birth defects, and/or other reproductive harm. For
more information, go to www.P65warnings.ca.gov
8 5 3 9 1 3 - 0 7 0 4 L
Ph. 800-750-2723

Publicité

loading

Sommaire des Matières pour Ashley AP5613-P

  • Page 1 Owner’s Instruction and Operation Manual Model Number: AP5613, AP5613-P, AP5613-L Report Number: F22-771 Certified to ASTM E1509-12 (2017) and Certified to ULC-S627-00-REV1 Mobile Home Approved 8 5 3 9 1 3 - 0 7 0 4 L * All Pictures In This Manual Are For Illustrative Purposes Only. Actual Product May Vary.
  • Page 2 INTRODUCTION Your pellet stove has been approved for installation in the USA and Canada. It may also be installed in a manufactured or mobile home. Your stove is Certified to ASTM E1509-12 (2017)and Certified to ULC S627-00. This manual describes the installation and operation of the U.S. Stove, 5710-XH wood heater. This heater meets the 2020 U.S.
  • Page 3 INSTALLATION CHECKLIST Your Wood Stove should be installed by a qualified installer only. An NFI qualified Installer can be found at www.nficertified.org/public/find-an-nfi-pro/ CUSTOMER SERVICE 1-800-750-2723 ext 5050 Text to 423-301-5624 Email to: Customerservice@usstove.com COMMISSIONING CHECKLIST This Checklist is to be completed in full by the qualified person who installs this unit. Keep this page for future reference.
  • Page 4 ASSEMBLY INSTRUCTIONS FOR CUSTOMER SERVICE CALL: 800-750-2723 EXT 5050 Pull the factory installed wires out of the top of 3. Connect the factory installed wiring harnesses the stove. There will be two wire harnesses, as to the control panel as shown. shown.
  • Page 5 INSTALLATION SAFETY NOTICE CAUTION: • IF THIS STOVE IS NOT PROPERLY INSTALLED, BURNING FUEL CREATES CARBON MONOXIDE A HOUSE FIRE MAY RESULT. TO REDUCE THE AND CAN BE HAZARDOUS TO YOUR HEALTH RISK OF FIRE, FOLLOW THE INSTALLATION IF NOT PROPERLY VENTED. INSTRUCTIONS.
  • Page 6 INSTALLATION FOR CUSTOMER SERVICE CALL: 800-750-2723 EXT 5050 IMPROPER INSTALLATION CLEARANCES The use of other components other than stated Your pellet stove has been tested and listed herein could cause bodily harm, heater damage, for installation in residential, mobile home in and void your warranty.
  • Page 7 INSTALLATION OUTSIDE AIR SUPPLY through both a hearth pad, if used, and the floor of the (OPTIONAL, UNLESS INSTALLING IN A MOBILE HOME) home. Depending your location home • The heater must be electrically grounded to the steel construction, outside air may be necessary for chassis of the mobile home with 8 GA copper wire optimal performance.
  • Page 8 INSTALLATION draft to reduce the possibility of smoke or odor exhaust flow and performance of the stove. Each during appliance shutdown and keep exhaust from elbow or tee reduces draft potential by 30% to 50%. causing a nuisance or hazard by exposing people All joints in the vent system must be fastened by or shrubs to high temperatures.
  • Page 9 INSTALLATION A. Minimum 4-foot (1.22m) clearance below or with a kit that will handle most of this installation, beside any door or window that opens. which will include a wall thimble that will allow the proper clearance through a combustible B.
  • Page 10 INSTALLATION Mark the area and then cut the wall for vent installation if needed. 2. Install the wall thimble as specified by the manufacturer. (wall thimble sold separately) 3. Install venting. Existing Class ‘A’ VENTING YOUR PELLET STOVE INTO AN 6”...
  • Page 11 OPERATION INSTRUCTIONS NEVER OPERATE THIS PRODUCT WHILE UNATTENDED PANEL CONTROLS C. °C / °F Button • The °C / °F button changes the two digit display from degrees Celsius to degrees Fahrenheit. D. MODE (M/T) BUTTON • The Mode of the stove can be switched between manual and controlled with a Thermostat.
  • Page 12 OPERATION INSTRUCTIONS pellets, move the fuel adjuster down. 10. Salt water driftwood or other previously salt water saturated materials; Turn off and unplug the appliance. 11. Unseasoned wood; or 2. Loosen the two wing-nuts. 12. Paper products, cardboard, plywood, 3. Adjust up to increase, or down to reduce the particleboard.
  • Page 13 OPERATION INSTRUCTIONS pellets. The stove’s performance depends heavily emit an odor as the high-temperature paint cures on the quality of your pellet fuel. Avoid pellet brands or becomes seasoned to the metal. Maintaining that display these characteristics: smaller fires will minimize this. Avoid placing items on the stovetop during this period because the paint •...
  • Page 14 OPERATION INSTRUCTIONS OPENING DOOR WARNING: • KEEP HOPPER LID CLOSED AT ALL TIMES CAUTION: EXCEPT WHEN REFILLING. • DO NOT OPERATE YOUR STOVE WITH THE • DO NOT OVERFILL HOPPER. VIEWING DOOR OPEN. THE AUGER WILL NOT FEED PELLETS UNDER THESE CIRCUMSTANCES AND A SAFETY CONCERN MAY ARISE FROM TAMPER WARNING SPARKS OR FUMES ENTERING THE ROOM.
  • Page 15 OPERATION INSTRUCTIONS OPTIMAL OPERATION If a vacuum is used to clean your stove, we suggest This pellet stove has been certified by the US EPA using the AV15E AshVac vacuum. The AV15E AshVac to meet strict 2020 guidelines. To Insure this unit is designed for ash removal.
  • Page 16 MAINTENANCE NEVER OPERATE THIS PRODUCT WHILE UNATTENDED heating season the entire system be professionally CAUTION: inspected, cleaned and, if necessary, repaired. To • FAILURE TO CLEAN AND MAINTAIN THIS clean the chimney, disconnect the vent from the UNIT AS INDICATED CAN RESULT IN POOR stove.
  • Page 17 MAINTENANCE PAINTED SURFACES 4. Reinstall the burn pot. Painted surfaces may be wiped down with a damp SMOKE & CO MONITORS cloth. If scratches appear, or you wish to renew your paint, contact your authorized dealer to obtain a Burning wood naturally produces smoke and can of suitable high-temperature paint.
  • Page 18 MAINTENANCE any screens on the exhaust system and on the necessary. outside air intake pipe. Turn all of the controls on Monthly or Daily Weekly and make sure that they are working properly. This as needed is also a good time to give the entire stove a good Burn Pot Stirred Empty...
  • Page 19 TROUBLESHOOTING GUIDE When your stove acts out of the ordinary, the first reaction is to call for help. This guide may save time and money by enabling you to solve simple problems yourself. Problems encountered are often the result of only five factors: 1) poor fuel;...
  • Page 20 TROUBLESHOOTING GUIDE Display is Flashing “E2” Possible Causes Possible Remedies: (Unplug stove first when possible) Unhook air hose from the air switch and blow through it. If air Airflow switch hose or stove attachment pipes flows freely, the hose and tube are fine. If air will not flow throw for hose are blocked.
  • Page 21 TROUBLESHOOTING GUIDE Display is Flashing “E3” Possible Causes Possible Remedies: (Unplug stove first when possible) The hopper is out of pellets Refill the hopper. The air dampener is too far open for a low feed If on the low setting, you may need to close the dampener all the setting way.
  • Page 22 TROUBLESHOOTING GUIDE Display is Flashing “E4” Possible Causes Possible Remedies: (Unplug stove first when possible) The air inlet, burnpot, interior combustion air Follow all cleaning procedures in the maintenance section of the chambers, combustion blower, or exhaust pipe owner’s manual. are blocked with ash or foreign material.
  • Page 23 TROUBLESHOOTING GUIDE Stove Feeds Pellets, But Will Not Ignite Possible Causes Possible Remedies: (Unplug stove first when possible) In some situations it may be necessary to have the damper Air damper open too far for ignition. completely closed for ignition to take place. After there is a flame, the damper can then be adjusted for the desired feed setting.
  • Page 24 TROUBLESHOOTING GUIDE Stove Will Not Feed Pellets, But Fuel Feed Light Comes On As Designed Possible Causes Possible Remedies: (Unplug stove first when possible) Wait for the stove to cool for about 30 - 45 minutes. Locate the High Limit thermodisc and press the reset button on the back High limit switch has tripped or is defective.
  • Page 25 TROUBLESHOOTING GUIDE Glass “Soot’s” Up At A Very Fast Rate Flame Is Lazy, Dark, And Has Black Tips After Stove Has Been On For A While, The Burnpot Overfills Possible Causes Possible Remedies: (Unplug stove first when possible) Stove or vent pipe is dirty, which restricts airflow Follow all cleaning procedure in the maintenance section of the through the burnpot.
  • Page 26 To order parts: Call 1-800-750-2723 Ext 5051 or Email to: parts@usstove.com IN ORDER TO MAINTAIN WARRANTY, COMPONENTS MUST BE REPLACED USING ASHLEY PARTS PURCHASED THROUGH YOUR DEALER OR DIRECTLY FROM ASHLEY. USE OF THIRD PARTY COMPONENTS WILL VOID THE WARRANTY.
  • Page 27 WIRING DIAGRAM 7.5A 250V FUSE 1.25A 250V FUSE Ensure the wires are connected to the bottom two prongs of the hopper switch as shown. CORRECT WRONG © 2022 United States Stove Company...
  • Page 28 NOTES © 2022 United States Stove Company...
  • Page 29 SERVICE RECORD It is recommended that your heating system is serviced regularly and that the appropriate Service Interval Record is completed. SERVICE PROVIDER Before completing the appropriate Service Record below, please ensure you have carried out the service as described in the manufacturer’s instructions. Always use the manufacturer's specified spare part when replacement is necessary.