Noise/vibration information
GDR 18V-210 C / GDX 18V-210 C:
Noise emission values determined according
to EN 62841-2-2.
Typically, the A-weighted noise level of the power tool is:
Sound pressure level 96 dB(A); sound power
level 107 dB(A). Uncertainty K = 3 dB.
Wear hearing protection!
GDS 18V-210 C:
Noise emission values determined according to
EN 62841-2-2.
Typically, the A-weighted noise level of the power tool is:
Sound pressure level 97 dB(A); sound power level
108 dB(A). Uncertainty K = 3 dB.
Wear hearing protection!
Vibration total values a
(triax vector sum) and uncertainty
h
K determined according to EN 62841-2-2:
Impact tightening of fasteners of the maximum capacity of
the tool:
GDR 18V-210 C: a
= 10 m/s
2
, K = 1.5 m/s
h
GDX 18V-210 C: a
= 9 m/s
2
, K = 1.5 m/s
h
GDS 18V-210 C: a
= 12.5 m/s
h
The vibration level and noise emission value given in these
instructions have been measured in accordance with a
standardised measuring procedure and may be used to com-
pare power tools. They may also be used for a preliminary
estimation of vibration and noise emissions.
The stated vibration level and noise emission value repres-
ent the main applications of the power tool. However, if the
power tool is used for other applications, with different ac-
cessories or is poorly maintained, the vibration level and
noise emission value may differ. This may significantly in-
crease the vibration and noise emissions over the total work-
ing period.
To estimate vibration and noise emissions accurately, the
times when the tool is switched off or when it is running but
not actually being used should also be taken into account.
This may significantly reduce vibration and noise emissions
over the total working period.
Implement additional safety measures to protect the oper-
ator from the effects of vibration, such as servicing the
power tool and accessories, keeping their hands warm, and
organising workflows correctly.
Assembly
Remove the battery from the power tool before carry-
u
ing out work on the power tool (e.g. maintenance,
changing tool, etc.). The battery should also be re-
moved for transport and storage. There is risk of injury
from unintentionally pressing the on/off switch.
Bosch Power Tools
2
2
, K = 1.5 m/s
2
2
Charging the Battery
Use only the chargers listed in the technical data. Only
u
these chargers are matched to the lithium-ion battery of
your power tool.
Note: The battery is supplied partially charged. To ensure
full battery capacity, fully charge the battery in the charger
before using your power tool for the first time.
The lithium-ion battery can be charged at any time without
reducing its service life. Interrupting the charging process
does not damage the battery.
The lithium-ion battery is protected against deep discharge
by the "Electronic Cell Protection (ECP)". When the battery
is discharged, the power tool is switched off by means of a
protective circuit: The accessory no longer rotates.
Do not continue to press the On/Off switch after the
u
power tool has automatically switched off. The battery
can be damaged.
Follow the instructions on correct disposal.
Removing the Battery
The battery (4) is equipped with two locking levels to pre-
vent the battery from falling out when pushing the battery re-
lease button (5) unintentionally. As long as the battery is in-
serted in the power tool, it is held in position by means of a
spring.
To remove the battery (4), press the release button (5) and
pull the battery out of the power tool. Do not use force to
do this.
Battery charge indicator
The green LEDs on the battery charge indicator indicate the
state of charge of the battery. For safety reasons, it is only
possible to check the state of charge when the power tool is
not in operation.
Press the button for the battery charge indicator or
show the state of charge. This is also possible when the bat-
tery is removed.
If no LED lights up after pressing the button for the battery
charge indicator, then the battery is defective and must be
replaced.
Battery model GBA 18V...
LEDs
3× continuous green light
2× continuous green light
1× continuous green light
1× flashing green light
English | 19
to
Capacity
60−100 %
30−60 %
5−30 %
0−5 %
1 609 92A 8XL | (31.08.2023)