4) OPERATION AND CONTROL
Set the main switch "0/1" located on the side of the product to its "1" position. I made sure the indicator light is on.
Then, to be able to use the remote control, remove the protective film as shown below. Always point the remote control
towards the side of the product where the receiver is located, indicated by the icon:
INSTRUCTIONS FOR CONTROLLING THE RESPIRO N MODELS
Press the ON/OFF key on the remote control and the product will start working. The front blind will
open automatically first. It takes a few minutes to fully open.
Using the V+ / V- keys you can select up to 3 speeds operation that suits you: Fast / Medium / Slow.
The product will automatically perform cycles of about 70 seconds in extraction mode and 70 seconds
in air intake mode.
Note: Using the OFF key on the remote control, the product will stop working and the blinds will re-
main open. If you want to completely switch off the product and close the blinds, disconnect the main
switch, in its "0" position.
INSTRUCTIONS FOR CONTROLLING THE RESPIRO RD N MODELS
LIST COMMANDS
S
Surveillance function
A
Automatic mode
V
Speed selection
H
Selection of relative humidity threshold
F
Direction of airflow
I
Air intake function
E
Air extraction function
S: Surveillance function (standby mode)
By pressing the "SURVEILLANCE" button, the product stays in standby mode with the damper closed but with the sen-
sors active. If the remove humidity parameters should exceed those set, the product automatically starts extracting the
air at the maximum speed until the values are restored and then returns to standby mode. In the case of several units,
all the units go into SURVEILLANCE mode. This function is very useful if the user is absent for long periods.
Response:
Light pulse on activating the mode
Periodic light pulse (every 1 min.) active mode
Constant light pulse Beyond Threshold value
S
V3
H3
V2
H2
V1
H1
A
F1
F2
I
E
Red
White/Red
Red
EN