Fault
Insufficient water
Crossflow, hot water being forced into
cold water pipe, or vice versa, when
mixer is closed
Spout temperature does not
correspond with temperature set
Temperature regulation not possible
Instantaneous heater didn't work with
thermostat
Diverter stiff
Shower or spout dripping
English
Cause
- Supply pressure inadequate
- Regulator filter dirty
- Shower filter seal dirty
- Backflow preventers dirty or leaking - Clean backflow preventers,
- Thermostat has not been adjusted
- Hot water temperature too low
- thermo cartridge calcified
- Filters are dirty
- check valve hasn't moved back
- Flow limiter in handshower isn't
removed
- Diverter defective
- Dirt or sedimentation on valve seat,
shut-off unit damaged
Assembly (see page 8)
Remedy
- Check water pressure (If a pump has
been installed check to see if the
pump is working).
- Clean filter in front of the mixer and
on the MTC-thermo cartridge
- Clean filter seal between shower
and hose
exchange if necessary
- Adjust thermostat
- Increase hot water temperature to
42 °C to 60 °C
- Exchange thermo cartridge
- Clean the filter / exchange filter
- Exchange check valves
- Remove flow limiter
- Exchange diverter
- Clean or exchange shut-off unit
5