Make sure about the way on how to connect the power cable to avoid the possibility of
-
sliding and tripping
It is user responsibility that the connection of the machine to the electric system is in
-
compliance with the rules in force in the country where the machine is installed, and it
has been made by a qualified technician.
Once all preliminary controls have been correctly done, use the main power switch to
-
start your machine
USE OF THE MACHINE
This machine is equipped with an innovative technology suitable to reach high performances with energy saving (up to 50% less compared
to other machines with same performances).
The electronic card supplies the welding bar with the correct power, changing automatically the welding time, depending on the network
voltage; the seal control is a balance between electronic (automatic) and user (manual) setting.
Once connected, the machine is ready for use by pressing the main power switch (11) if
present. Correct vacuum packaging extends food storage time.
The appliance is intended to be used with RGV embossed bags of the same type as furnished with the machine, if used with
different or other label bags the machine may not have same performances.
This appliance is not intended for use with high grade humidity food; liquids suction may damage the appliance (pump, el. card
and vacuum chamber gasket) and this is considered inappropriate use and out of warranty cover.
Correct storage:
Bags and appliance must be stored in a dry and no dust place with temperature between +10° to +30°.
VACUUM PACKAGING IN BAGS AUTOMATIC USE
-
Prepare the food which is to be vacuum preserved taking off every thorns or spikes could pierce the bag, in an embossed bag of
adequate size, leaving about 5 cm from the edge of the bag and the food.
Lift the cover up (4).
-
Place the open side of vacuum bag in the vacuum chamber (6), between the gaskets (5). Close the cover and press pump
-
switch (1). This will start vacuum operation.
As soon as vacuum pump starting, slightly press with both hands the cover so as it sticks to the surface of the bag. After a few
-
seconds the depression created by the pump will permit to release the cover, while the machine will keep on suction.
Seal will start automatically and the machine will automatically stop at the end of the cycle.
-
USER INTERVENTION
Every operation will stop when pressing pump switch (1).
-
It is possible to start sealing cycle when a correct vacuum level is attended (between the two black lines on green space of the
-
manometer), by pressing welding switch (2). Low vacuum level could affect welding efficiency, if cover (4) doesn't exert a
minimum power on the welding bar.
BE CAREFUL: pressing the welding switch (2) after the start of automatic welding will end welding operation.
-
USE OF ROLLS - welding without vacuum
Lift the cover (4) and place the roll (in well spread conditions) on the welding bar. Make sure that the open side of the roll is NOT
-
inside the vacuum chamber (6).
-
Start the air pump by pressing switch (1). Slightly press your hands on the cover (6) to close the vacuum chamber.
-
When the vacuum level is reached, welding starts automatically. -
- After welding the unit stops. Cut the roll and use like a bag.
ELECTRONIC SETTINGS
Default set:
1-
Minimum electronic power of sealing of 2 units time/power, suitable for 95/105 microns bags furnished.
2-
Seal power setting via switches is allowed.
4-
3-
The machine is set by automatic cycle vacuum/seal,
5-
It is possible to set to manual cycle by programming the electronic card.
6-
The machine is set by 10 secs. delay from reaching vacuum level before welding start (to reach more vacuum); this delay time
can be set by programming the electronic card.
7-
The machine is set by a waiting time at the end of welding to obtain a best quality seal; this waiting time can be stopped by press
the start switch (1) when the Led (12) is off, showing the end of welding operation.
8-
The first three operating cycles are designed to deliver 20% more welding power to improve welding in the case of a cold
machine; after each cycle of use, the appliance must be disconnected from the network to restore this function.
INFO
Welding time could be different using different kind of bags even if thickness is the same; we suggest to test welding after changing
welding time. Less seal power = faster cycle.
IMPORTANT
If the machine is not used for a long period and/or in the case of non-adequate or low temperatures, it is recommendable, before using the
machine, to try it once without using the bag and keep the machine working in automatic cycle for one/two cycles.
WELDING POWER SETTING
To change welding power on appliances not equipped with potentiometer:
1-
Connect appliance to power supply.