3. After inserting the water pipe to the
union, install it to the tap adaptor
and insert to the tap as shown in the
figure. (Figure C)
4. Tighten the union manually. In case of
a leak use a spanner or a pair of pliers
to tighten the union.
A
Warning: Secure the water pipe
to suitable points by means of the
pipe clips supplied to avoid any
damage or displacement or accidental
disconnection.
A
Warning: After turning on the water
valve, make sure that there is no
leakage at both connection points of
the water pipe. In case of a leak, turn
off the valve immediately and tighten all
joints again using a spanner or a pair
of pliers.
A
Warning: Make sure that standard
1/2" valve fitting fed by cold mains
water supply is available and is turned
off fully.
Note -1: There is no need to use water
filter in case a jug is used.
Note -2: Pump must be used when jug
will be used.
Prior to first use of Ice/Water
Dispenser
C
Water mains pressure must not be
below 1 bar.
C
Water mains pressure must not be
over 8 bars.
C
Pumps must be used in case the
supply water pressure drops below 1
bar or if a jug is going to be used.
C
Water system of the refrigerator
must be connected to the cold water
line. It must not be connected to hot
water line.
17