Grounded
Outlet
Grounding
Plug
Grounding Instructions
WARNING: Risk of electric shock, fire, or personal injury.
This product must be grounded and connected only to a
dedicated, nominal 120 VAC, 60 Hz circuit protected by a
minimum 15 A Ground-Fault Circuit-Interrupter (GFCI)* or
Residual Current Device (RCD).
This product should be grounded. In the event of an electrical
short circuit, grounding reduces the risk of electric shock by
providing an escape wire for the electric current. This product is
equipped with a cord having a grounding wire with a grounding
plug. The plug must be plugged into an outlet that is properly
installed and grounded.
DANGER: Risk of electric shock. Improper use of the
grounding plug can result in a risk of electric shock.
If repair or replacement of the cord or plug is necessary, do not
connect the grounding wire to either flat blade terminal. The wire
with insulation having an outer surface that is green with or
without yellow stripes is the grounding wire.
Check with a qualified electrician or service personnel if the
grounding instructions are not completely understood, or if in
doubt as to whether the product is properly grounded.
CAUTION: Risk of property damage. A single extension
cord may be used provided that the cord type begins with
"SJ", is 12-gauge, grounded (12/3), not longer than 25 feet (7.6
meters), and plugged into a GFCI* electrical outlet. Promptly
replace any extension cord that exhibits any sign of damage.
* * Outside North America, this device may be known as a Residual
Current Device (RCD).
1441872-5-B