2-Blinking Yellow Light provides notification that a CO WATCH-GUARD fault has occurred and no longer
provides protection. The generator is shutoff automatically and the yellow light will blink for at least five minutes
after shutoff. Call A-iPower Customer Service 855-888-3598 for repair. Do not use the generator until the
sensor is working properly. The CO WATCH-GUARD must only be serviced by qualified technician to restore it
to original settings.
WARNING
DO NOT modify or tamper with the Carbon Monoxide Detecting System (CO WATCH-GUARD). Not following
these instructions could result in death or serious injury due to Carbon Monoxide detecting system malfunction.
CO WATCH-GUARD will detect the accumulation of carbon monoxide from other fuel burning sources such as
engine powered tools used in the area of operation. If another generator is used and the exhaust is pointed at a
CO WATCH-GUARD equipped generator, the CO WATCH-GUARD may initiate a shutoff due to rising carbon
monoxide levels. This is not a fault. Hazardous carbon monoxide has been detected. You must take action to
move and direct the equipment to better dissipate carbon monoxide far away from people or buildings.
CO WATCH-GUARD only monitors when the generator is running.
CO WATCH-GUARD DOES NOT replace carbon monoxide alarms.
Tempering with the CO WATCH-GUARD will void your warranty.
WARNING
Tampering with CO WATCH-GUARD could result in a hazardous condition. Removing the CO WATCH-GUARD
module will not allow the generator to start.
120V AC, 20A Duplex GFCI
Your generator is equipped with ground fault circuit interrupter (GFCI) receptacles. In the event of a ground fault,
a GFCI trips automatically to stop the flow of electricity and prevent serious injury. The LED Indicator Light on
the receptacle will be turn off. Press the "RESET" button located on the front of the receptacle to restore flow of
electricity. GFCI does NOT protect against circuit overloads. To ensure proper operation of the GFCI duplex,
perform this test monthly:
1. With the generator running, plug a test lamp into the GFCI receptacle. Turn the lamp on.
2. Press the "TEST" button located on the front of the receptacle to trip the device. This should immediately stop
the flow of electricity and shut off the lamp. If the electricity is not stopped, do not use this receptacle until it has
been serviced or replaced.
3. Press the "RESET" button located on the front of the receptacle to restore the flow of electricity. If the LED
Indicator Light does not come back or GFCI cannot be reset, then it must be replaced.
Receptacle
Outlet
LED Indicator Light
Reset Button
Test Button
Outlet
RESET
TEST