1. Hour Meter: Displays and records how many
hours your generator has run (up to 9,999.9).
2. Low Oil Indicator: The Light will be illuminated
when the engine oil level is low. Add oil.
3. CO(Carbon Monoxide) WATCH-GUARD Indicator
Light (Red for Shutoff and Yellow for Service):
The CO(Carbon Monoxide) WATCH-GUARD
monitors for the accumulation of poisonous CO
gas around the generator produced by engine
exhaust when the generator is running. If the CO
WATCH-GUARD detects increasing levels of CO
gas, it automatically shuts off the engine. See CO
WATCH-GUARD section for more information.
4. Main Breaker: The main breaker controls total
output of all outlets to protect the generator from
overload or short circuit.
5. 120V AC, 20A Duplex, GFCI, Single Phase, 60 Hz
Outlets (5-20R): Each outlet is capable of
carrying a maximum of 20 amps on a single outlet
or a combination of both outlets.
NOTE: Total power drawn from all outlets must not exceed the nameplate rating.
4
5
9
6
5
10 6
6. Circuit Breaker: Protects the generator against
electrical overloads.
7. 120/240V AC, 50A, Single Phase, 60 Hz Outlet
(NEMA 14-50R): This outlet can supply either 120
Volt or 240 Volt output up to 50 amps.
8. Engine Control Switch: To start engine manually,
flip the switch to RUN (I)
starter. To start engine with electric start, press
and hold the switch on the START (II)
and the engine will crank and attempts to start.
When the engine starts, release the switch to the
RUN (I)
position.
9. 12V DC, Outlet (Automotive): Provides 12 volt DC
power up to 8.3 amps.
10. Ground Terminal: The ground terminal is used to
ground the generator.
11. 120/240V AC, 30A Twist Lock, Single Phase,
60 Hz Outlet (NEMA L14-30R): This outlet can
supply either 120 Volt or 240 Volt output up to
30 amps.
Page 10
7
6
11
position and pull recoil
position