Existing Construction
B11
EXISTING FAN
Remove an existing fan and check to make sure the
opening is large enough to accommodate the new
motor housing (7 1/4"x 7 3/4").
B13
Route wires through strain relief
B15
Screw pre-loaded screws into joist or framing
.
E
.
B12
Move the housing into position above the ceiling.
B14
Attach existing ducting to duct connector. Tape joints.
If ducting does not fit securely,
an adapter may need to be purchased.
8
E
41946-01 R111207