Télécharger Imprimer la page

SOMFY LEVIXO 30 RTS Manuel D'installation page 33

Publicité

Les langues disponibles

Les langues disponibles

Levixo 30-50 RTS
8. PARAMETER SETTING
Potentiometers: to modify the automatic closing time and the motor run time.
1
TCA:
2
Automatic
closing time
3
TW:
4
Motor run time
5
DIP switch: to select the operating mode for the motor and its additional devices.
6
1:
7
Automatic
closing
8
2:
Operation of the
photoelectric
+
cells
-
+
3:
Blocking
-
impulses
4:
3 Step/4 Step
5
6
7
8
9. CLEARING ALL REMOTE CONTROLS
Press the PROG button of the control unit
(for more than 7 seconds) until the indicator
All the remote controls and radio control points
are erased.
10. MAINTENANCE
Before performing any operations inside the housing, it is essential to ensure that the spring is released by
moving the boom to the vertical position.
Lock the boom by placing the key in the padlock closed position
Before carrying out work on the installation, switch off the power supply.
Clean the photoelectric cell optical units regularly.
Copyright © 2011 Somfy SAS. All rights reserved.
Between 0 and 90 seconds
Between 0 and 120 seconds
ON: Activates automatic closing
OFF: Deactivates automatic
closing
ON: In closing mode only.
OFF: In opening and closing
mode.
ON: In opening mode only
OFF: None
ON: Activates the 3 step logic.
OFF: Activates the 4 step
logic.
DIP 5 and 6 are not used and have no effect.
OFF: Compulsory position
OFF: Compulsory position
>7s
Setting the time delay for automatic closing (if
DIP1 is ON).
The motor run time should be slightly longer
than the actual closing time of the barrier.
The barrier closes automatically after the
programmed time delay (TCA).
In closing mode, the barrier stops then
reverses its movement.
In opening mode, the cells are inactive.
In closing mode, the barrier stops and
reverses its movement once the cells are
no longer obstructed.
In opening mode, the barrier stops then
continues its movement once the cells are
no longer obstructed.
Impulses during opening have no effect.
3 STEP = operation in semi-automatic mode
(see "User's manual" p. 1).
4 STEP = operation in sequential mode (see
"User's manual" p. 1).
.
13

Publicité

loading

Ce manuel est également adapté pour:

Levixo 50 rts