Mounting And Operation - HIKOKI CV 18DBL Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 15
English
Before
charging
While charging Lights
Charging
complete
Pilot lamp
(red)
Overheat
standby
Charging
impossible
● Regarding the temperatures and charging time of the
battery.
The temperatures and charging time will become as
shown in Table 2.
Battery
Charging voltage
Weight
Temperatures at which the battery
can be recharged
Charging time for battery capacity,
approx. (At 20oC)
1.5 Ah
2.0 Ah
2.5 Ah
3.0 Ah
4.0 Ah
5.0 Ah
Number of battery cells
NOTE
The recharging time may vary according to temperature
and power source voltage.
CAUTION
When the battery charger has been continuously used,
the battery charger will be heated, thus constituting
the cause of the failures. Once the charging has been
completed, give 15 minutes rest until the next charging.
4. Disconnect the charger's power cord from the
receptacle.
5. Hold the charger fi rmly and pull out the battery.
NOTE
Be sure to pull out the battery from the charger after use,
and then keep it.
CAUTION
○ If the battery is charged while it is heated because it has
been left for a long time in a location subject to direct
sunlight or because the battery has just been used, the
pilot lamp of the charger lights for 1 second, does not
light for 0.5 seconds (off for 0.5 seconds). In such a case,
fi rst let the battery cool, then start charging.
Indications of the pilot lamp
Lights for 0.5 seconds. Does not light for 0.5
Blinks
seconds. (off for 0.5 seconds)
Lights continuously
Lights for 0.5 seconds. Does not light for 0.5
Blinks
seconds. (off for 0.5 seconds)
Lights for 1 second. Does not light for 0.5
Blinks
seconds. (off for 0.5 seconds)
Lights for 0.1 seconds. Does not light for 0.1
seconds. (off for 0.1 seconds)
Flickers
Table 2
Charger
UC18YFSL
V
14.4 – 18
kg
0.5
0oC – 50oC
min.
22
min.
30
min.
35
min.
45
min.
60
min.
75
4 – 10
Table 1
○ When the pilot lamp fl ickers (at 0.2-second intervals),
check for and take out any foreign objects in the charger's
battery connector. If there are no foreign objects, it is
probable that the battery or charger is malfunctioning.
Take it to your authorized Service Center.
○ Since the built-in micro computer takes about 3 seconds to
confi rm that the battery being charged with charger is taken
out, wait for a minimum of 3 seconds before reinserting it
to continue charging. If the battery is reinserted within 3
seconds, the battery may not be properly charged.
○ If the pilot lamp does not blink in red (every second)
even though the charger cord is connected to the power,
it indicates that the protection circuit of the charger may
be activated.
Remove the cord or plug from the power and then
connect it again after 30 seconds or so. If this does
not cause the pilot lamp to blink in red (every second),
please take the charger to the HiKOKI Authorized
Service Center.

MOUNTING AND OPERATION

Action
Removing and inserting the
battery
Charging
Remaining battery indicator
How to use the LED light
Mounting the application tool
Switch Operation
Adjusting operating speed
Sawing
Sanding
Selecting accessories
The tool is equipped with two modes: "Standard Mode" and
"AUTO Mode".
(1) Standard Mode
You can change the vibration frequency between 6000
to 20000 min
by adjusting the dial from "1" to "5".
-1
(2) AUTO Mode
Depending on the workload, AUTO Mode "A" will
automatically change the vibration frequency to 15000
min
or 20000 min
-1
vibration and noise prior to and during operation.
6
Battery overheated.
Unable to charge.
(Charging will
commence when
battery cools)
Malfunction in the
battery or the charger
Figure
1
2
3
4
5
6
7
*1
8
9
*2
. This has the eff ect of lowering
-1
Page
147
147
147
147
148
149
149
149
149
150

Publicité

Table des Matières
loading

Table des Matières